{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1201K7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1201K7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1201K7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1201K7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K1201K7, 3P, AC-3 12A at ≤440V, 100V AC coil, IP20, depth 57 mm.","salesMarkdown":"The unit is rated for utilization categories AC-1, AC-3, and AC-4, with a specific AC-3 rating of 12 A at ≤440 V. The AC-4 rating covers plugging and inching duty, so the contactor is rated for the higher switching frequency and electrical wear those operations demand. The 100 V AC coil means the control circuit must supply 100 V AC nominal; verify your control transformer or PLC output matches this voltage, as a mismatch will prevent pickup or cause coil burnout. ## Physical Integration and Compliance The contactor measures 90 mm wide by 58 mm high by 57 mm deep. These dimensions fit a standard DIN-rail footprint for the TeSys K form factor; plan for the depth when routing wiring behind the panel. The flame retardance rating is V1 per UL 94, and it also meets NF F 16-101 and NF F 16-102 requirements—relevant for rail or transit applications where fire-smoke-toxicity standards apply. Operating altitude is 2000 m without derating; above that, the dielectric withstand and thermal dissipation will need recalculation. The protective treatment conforms to IEC 60068 and DIN 50016 for resistance to corrosive atmospheres.","metaTitle":"Schneider TeSys K LC2K1201K7 Reversing Contactor, 3P, 12A AC","metaDescription":"Obsolete Schneider TeSys K reversing contactor LC2K1201K7, 3P, 12A AC-3 at ≤440V, 100V AC coil. Sourced to order against RFQ. Depth 57 mm. UL 94 V1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/77852d1ee938c48332ee299079452aa9.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K1201K7/reversing-contactortesys-k3pac3440v-12a1nc100v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1201K7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"The LC2K1201K7 is a 3-pole reversing contactor rated 12 A in AC-3 duty at ≤440 V, with a 100 V AC coil. It covers utilization categories AC-1, AC-3, and AC-4. Dimensions are 90 x 58 x 57 mm (WxHxD)."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries a V1 flame retardance rating per UL 94, and also conforms to NF F 16-101 and NF F 16-102 for rail applications. The protective treatment follows IEC 60068 and DIN 50016. The IP20 degree of protection is per VDE 0106. Standard Schneider documentation for the TeSys K range applies."},{"question":"What is the depth of the LC2K1201K7?","answer":"The depth is 57 mm. This is the dimension behind the panel face, critical for enclosure depth clearance and wiring bend radius."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1201K7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1201K7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}