{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1201Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1201Q7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1201Q7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1201Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K1201Q7, 3P, AC-3 12A at 440V, 380-400V AC coil, 1 NC auxiliary, preassembled with reversing power busbar.","salesMarkdown":"The contactor carries a single NC auxiliary contact and is rated for AC-1 (resistive) and AC-4 (plugging/inching) duty as well, giving flexibility beyond pure motor switching. IP20 finger-safe terminals per VDE 0106 suit it for enclosed panel mounting. For a BOM replacement, a parametric cross-reference to a current TeSys K or TeSys Deca reversing contactor with matching pole count, coil voltage, and AC-3 rating would be the practical path — but that requires engineering review of the mounting footprint and auxiliary configuration. The AC-4 rating covers the more demanding reversing and plugging duty, where the contactor must interrupt locked-rotor current; that rating is typically lower than AC-3, so verify it against your application's inrush profile if frequent reversing is expected. Altitude derating starts above 2000 m. Flame retardance meets UL 94 V1 and NF F 16-101/102, relevant for rail and industrial compliance. Mechanical robustness is specified for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6, with the contactor closed handling up to 15 Gn on Y and Z axes.","metaTitle":"TeSys K LC2K1201Q7 Reversing Contactor, 3P, AC-3 12A, 380-40","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 12A at 440V, 380-400V AC coil, 1 NC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8a9ea6212382e2d5a11d20ed654db94a.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K1201Q7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-380-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1201Q7/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC2K1201Q7?","answer":"No official successor order code is provided in the lifecycle record. A parametric replacement from the current TeSys K or TeSys Deca range would need to match the 3-pole configuration, 380-400 V AC coil, AC-3 12 A rating, and the NC auxiliary contact — but this requires engineering verification of footprint and busbar arrangement."},{"question":"What are the key ratings of the LC2K1201Q7?","answer":"It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 380-400 V AC coil and one NC auxiliary contact. It covers AC-1 and AC-4 utilisation categories as well. The unit is preassembled with a reversing power busbar."},{"question":"What compliance documentation is available for the LC2K1201Q7?","answer":"The contactor carries IP20 finger-safe protection per VDE 0106, flame retardance to UL 94 V1 and NF F 16-101/102, and protective treatment per IEC 60068 and DIN 50016. Mechanical robustness is tested to IEC 60068-2-27 (shock) and IEC 60068-2-6 (vibration)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1201Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1201Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}