{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1201R7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1201R7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1201R7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1201R7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K1201R7, 3P, AC-3 ≤440 V 12 A, 1 NC, 440 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"It switches three poles (3 NO main contacts) and carries a single NC auxiliary contact. The 440 V AC coil pulls in on the control voltage common in European and Asian industrial panels. The AC-1 resistive rating covers heater banks or lighting circuits at the same current level. IP20 finger protection (VDE 0106) means it is safe for open-panel mounting inside an enclosure. Storage tolerance extends from -50 to 80 °C. ## Sourcing Reality — Obsolete, Sourced to Order Because it is a reversing contactor with a 440 V AC coil and a specific busbar assembly, a direct drop-in replacement from the current TeSys range may require a different coil voltage or a separate reversing kit. We can quote what is available on the open market; lead time and pricing vary by lot.","metaTitle":"Schneider TeSys K LC2K1201R7 Reversing Contactor, 12 A AC-3,","metaDescription":"Schneider Electric TeSys K LC2K1201R7 reversing contactor, 3P, 12 A at 440 V AC-3, 440 V AC coil, 1 NC auxiliary. Obsolete — sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/300532b3695f7b90c01ed186257cfeb2.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC2K1201R7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-440-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1201R7/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings for the LC2K1201R7?","answer":"It is a 3-pole reversing contactor rated 12 A in AC-3 duty at ≤440 V, with a 440 V AC coil. It also covers AC-1 (resistive) and AC-4 (plugging/inching) utilisation categories. The rated operational voltage on the power circuit is 690 V AC 50/60 Hz."},{"question":"What is the physical size of this contactor?","answer":"Width 90 mm, height 58 mm, depth 57 mm. It is preassembled with a reversing power busbar, so the overall width is the same as a single contactor footprint."},{"question":"What compliance standards does the LC2K1201R7 meet?","answer":"Flame retardance V1 per UL 94, plus NF F 16-101 and NF F 16-102 for rail. IP20 finger protection per VDE 0106. Protective treatment per IEC 60068 and DIN 50016. Shock and vibration tested per IEC 60068-2-27 and IEC 60068-2-6."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1201R7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1201R7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}