{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1201V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1201V7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1201V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1201V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 400 V AC coil, preassembled reversing busbar, IP20.","salesMarkdown":"The Schneider Electric TeSys K LC2K1201V7 is a three-pole reversing contactor rated AC-3 at 12 A up to 440 V with a 400 V AC coil, preassembled with a reversing power busbar so it arrives ready to wire into a motor-reversing circuit. It carries one normally-closed auxiliary contact and is IP20 finger-safe per VDE 0106, suited for enclosed control panels where personnel access is restricted. The AC-3 rating of 12 A at 440 V governs motor switching — this is the utilisation category for squirrel-cage motors during starting and plugging, so the contactor is sized for a motor drawing up to 12 A full-load current. The preassembled reversing busbar saves panel space and wiring time compared to building a reversing pair from two separate contactors plus a mechanical interlock.","metaTitle":"Schneider TeSys K LC2K1201V7 reversing contactor, 3P AC-3 12","metaDescription":"Schneider Electric TeSys K reversing contactor LC2K1201V7, 3P, AC-3 ≤440 V 12 A, 1 NC, 400 V AC coil. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0a84495cf3ef88a11eb6a6e43c93778e.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC2K1201V7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1201V7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative to LC2K1201V7 in this component family?","answer":"No official successor is listed in the available records. A parametric match within the TeSys K family would need the same pole count (3P), AC-3 current (12 A at 440 V), 400 V AC coil, and reversing configuration. Without a documented cross-reference, the safest path is to source the original order code against an RFQ."},{"question":"What compliance documentation does this brand provide for LC2K1201V7?","answer":"The contactor carries a V1 flame-retardance rating per UL 94 and meets NF F 16-101/102 for railway fire behaviour. It is also protected against corrosive atmospheres per IEC 60068 and DIN 50016 (TC treatment)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1201V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1201V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}