{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K12103L7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K12103L7","canonicalUrl":"https://aoctrl.com/schneider/LC2K12103L7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K12103L7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 200...208 V AC, preassembled with reversing power busbar.","salesMarkdown":"The 200-208 V AC coil matches common North American control voltages. The 3-pole, 3 NO main contact set switches the motor phases; the built-in 1 NO auxiliary contact can be used for seal-in or status feedback to a PLC input. AC-3 rating at 12 A is the motor-switching figure that governs real use — it covers inrush during starting and breaking under full load. The AC-1 rating (resistive load) will be higher, but for motor control the AC-3 number is the one that decides if the contactor lives in the application. The 690 V AC maximum on the power circuit gives headroom for 480 V systems with margin. Storage range of -50 to 80 °C matters for warehousing or shipping through unheated freight. Altitude rating to 2000 m without derating means it's fine for most sites; above that the air density drop reduces the arc-quenching ability, so derating applies. IP20 protection (VDE 0106) means finger-safe — no ingress of solid objects larger than 12 mm, but not sealed against dust or moisture. This is standard for a panel-mounted contactor; it expects to live inside an enclosure with at least an IP54 rating. No unusual lead-time risk or minimum-quantity constraints apply beyond what any active TeSys K line item carries.","metaTitle":"Schneider TeSys K LC2K12103L7 Reversing Contactor, 12 A AC-3","metaDescription":"Schneider Electric TeSys K reversing contactor LC2K12103L7, 3-pole, 12 A AC-3 at 440 V, 200-208 VAC coil. Active production, sourced to order. IP20, DIN-rail mount.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LC2K12103L7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-200-208-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K12103L7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"AC-3 motor-switching rating of 12 A at up to 440 V, with a 200-208 V AC coil. The power circuit is rated for 690 V AC 50/60 Hz. It is a 3-pole, 3 NO contact configuration with one built-in NO auxiliary contact."},{"question":"What compliance documentation is available for the LC2K12103L7?","answer":"The contactor carries a V1 flame retardance rating per UL 94, and also meets NF F 16-101 and NF F 16-102 railway fire standards. IP20 protection is per VDE 0106. The protective treatment conforms to IEC 60068 and DIN 50016 for environmental resistance."},{"question":"What are the physical dimensions of this contactor?","answer":"Width 90 mm, height 58 mm, depth 57 mm. It mounts on a standard DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K12103L7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K12103L7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}