{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1210R7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1210R7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1210R7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1210R7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys K reversing contactor, 3P, AC-3 12A at 440V, 1 NO, 440V AC coil, IP20.","salesMarkdown":"The LC2K1210R7 is a TeSys K reversing contactor from Schneider — a 3-pole unit preassembled with a reversing power busbar, rated for AC-3 motor duty at 12 A up to 440 V, with a 440 V AC coil and one normally open auxiliary contact. It's the kind of part you'd find in a panel controlling a small conveyor or pump motor where direction reversal is needed. The AC-3 rating at 12 A, 440 V tells you this contactor is sized for a motor load — not resistive heating. AC-3 covers starting and switching off squirrel-cage motors under load, so the 12 A figure governs the motor full-load current, not the inrush. The 440 V AC coil means the control circuit runs off a standard line-voltage signal, not a low-voltage PLC output — plan for a separate control transformer or direct line feed.","metaTitle":"Schneider LC2K1210R7 TeSys K Reversing Contactor, 12A AC-3,","metaDescription":"Obsolete TeSys K reversing contactor. 3P, AC-3 12A at 440V, 1 NO aux, 440V AC coil. IP20. Sourced to order against RFQ. Cross-reference available.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4f77cc7e6938ac3bfd65a4394f813ff3.pdf","sourceUrl":"https://www.se.com/nl/en/product/LC2K1210R7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-440-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1210R7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC2K1210R7 in the TeSys family?","answer":"Within the TeSys K series, the current-production equivalent would be a reversing contactor with the same pole configuration and AC-3 rating. The exact replacement depends on coil voltage and auxiliary contact count — the LC2K1210R7 uses a 440 V AC coil with one NO aux. A sourcing specialist can cross-reference to the active TeSys Deca or TeSys D series reversing contactors, which share the same footprint and mounting pattern, but verify the coil voltage matches your control circuit."},{"question":"What is the depth of LC2K1210R7?","answer":"The depth is 57 mm. That's the dimension from the mounting surface to the front of the contactor body, not including any protruding terminals or busbars."},{"question":"What compliance documentation is available for LC2K1210R7?","answer":"The contactor carries V1 flame retardance per UL 94 and meets NF F 16-101/102 for rail applications. It is IP20 rated per VDE 0106. Shock and vibration testing follows IEC 60068-2-27 and IEC 60068-2-6. Protective treatment conforms to IEC 60068 and DIN 50016. Specific RoHS/REACH declarations would be from the original manufacturer's documentation archive for this now-obsolete part."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1210R7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1210R7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}