{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1210V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1210V7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1210V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1210V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 400 V AC coil, IP20.","salesMarkdown":"It is a 3-pole device rated for AC-3 duty at 12 A up to 440 V, with a 400 V AC coil and one normally open auxiliary contact. The IP20 finger-safe enclosure (per VDE 0106) suits it for enclosed control panels where accidental contact with live parts must be prevented during maintenance. This order code is classified as Obsolete by the manufacturer. No official successor order code exists. The AC-3 rating of 12 A at 440 V governs motor switching: it handles starting and disconnecting squirrel-cage motors up to that current, covering small conveyors, pumps, and fans. The AC-1 rating (resistive load) is higher but not the limiting case for motor duty. The 400 V AC coil must match the control voltage in the panel — verify your control transformer taps before specifying. Dimensions of 90 mm wide by 58 mm high by 57 mm deep fit a standard DIN-rail footprint, but the reversing busbar adds width compared to a single contactor; check panel fill factor against the existing gland plate layout.","metaTitle":"Schneider Electric LC2K1210V7 TeSys K Reversing Contactor, 3","metaDescription":"Schneider Electric LC2K1210V7 TeSys K reversing contactor, 3P, AC-3 12A at 440V, 1NO, 400V AC coil. Obsolete — sourced to order against RFQ. IP20, V1 flame retardance.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3 AC-1","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6b9324ae91f88d9df4279820e9f6588c.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K1210V7/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1210V7/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LC2K1210V7?","answer":"No official successor order code is published for this part. Any replacement would need to be evaluated against the specific application — coil voltage, reversing busbar arrangement, and panel footprint — and would require a customer-approved alternate or deviation."},{"question":"What are the key ratings for the LC2K1210V7?","answer":"It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 400 V AC coil and one normally open auxiliary contact. The enclosure is IP20, and dimensions are 90 mm wide by 58 mm high by 57 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1210V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1210V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}