{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16015F72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16015F72","canonicalUrl":"https://aoctrl.com/schneider/LC2K16015F72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16015F72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NC, 110 V AC coil, IP20.","salesMarkdown":"The Schneider Electric TeSys K LC2K16015F72 is a reversing contactor — a preassembled unit with the reversing power busbar already fitted. It is a 3-pole device rated for AC-3 and AC-4 duty. The rating is 16 A at ≤440 V in AC-3. The coil is 110 V AC. The AC-4 rating covers reversing and plugging duty, where the contactor breaks at full load current, so that rating is typically lower; the evidence does not give a separate AC-4 current figure, but the dual utilization category confirms the contactor is built for the mechanical stress of frequent reversals. The 690 V AC rated operational voltage on the power circuit means it can also switch on a 690 V line if derated — but the 16 A AC-3 rating is only valid up to 440 V. Above that, the current must be reduced per the manufacturer's derating curve. The IP20 finger-safe terminals are standard for enclosed panel mounting; no washdown protection here. The shock and vibration ratings are solid for a reversing contactor that sees frequent mechanical cycling: it holds closed through 10 Gn on Y and Z axes, and 15 Gn on X. The V1 flame retardance rating per UL 94 means the housing material self-extinguishes — relevant for panel certification. The IP20 terminals accept standard ring or fork crimp lugs. The 1 NC auxiliary contact is built in — useful for a feedback signal to the PLC or to interlock the forward and reverse coils in the safety circuit. The coil is 110 V AC, so verify your control transformer voltage matches before wiring.","metaTitle":"TeSys K LC2K16015F72 Reversing Contactor, 3P, 16A AC-3, 110V","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 ≤440V 16A, 1 NC, 110V AC coil. IP20, 690V AC rated. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a57bd186cda2c0418e03b9291dcb084e.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC2K16015F72/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-nc-110-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K16015F72/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LC2K16015F72?","answer":"It is a 3-pole reversing contactor rated 16 A in AC-3 at ≤440 V, with a 110 V AC coil. The power circuit is rated for 690 V AC. It has IP20 finger-safe protection."},{"question":"How do I source this obsolete part?","answer":"Through the surplus and broker channel. We can quote it to order against an RFQ — there is no factory stock or lead time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16015F72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16015F72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}