{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16017Q7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16017Q7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16017Q7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16017Q7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NC, 380-400 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"The LC2K16017Q7 is a TeSys K reversing contactor from Schneider Electric, built as a 3-pole unit rated 16 A in AC-3 duty at up to 440 V, with a 380-400 V AC coil and one NC auxiliary contact. It comes preassembled with a reversing power busbar, so it's ready to wire into a motor-reversing circuit without piecing together interlocks and bus links. The AC-3 rating means it's designed for starting and stopping squirrel-cage motors under full load — the typical duty for a reversing starter on a conveyor, pump, or fan. ## Physical integration The preassembled reversing busbar saves panel space and wiring time compared to building the reversing interlock with separate contactors and external wiring.","metaTitle":"TeSys K LC2K16017Q7 reversing contactor, 3P, 16 A AC-3, 380-","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NC, 380-400 V AC coil. Sourced to order via RFQ. IP20, 57x90x58 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9b7e1838c0f0d31283075a1b76b7f603.pdf","sourceUrl":"https://www.se.com/in/en/product/LC2K16017Q7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-nc-380-400-v-ac/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K16017Q7/alternatives.json"},"ai":{"faq":[{"question":"What replaces this reversing contactor?","answer":"No official successor order code is listed. For a new design, move to a current TeSys D or TeSys F reversing contactor with the same pole count, AC-3 current rating, and coil voltage."},{"question":"What are the key ratings I need to check for fit?","answer":"AC-3 rating is 16 A at ≤440 V, coil is 380-400 V AC, 3 poles with one NC auxiliary. IP20, DIN rail mount, dimensions 57x90x58 mm."},{"question":"Does it come with the reversing busbar?","answer":"Yes, it's preassembled with a reversing power busbar, so it's ready to wire into a reversing motor circuit without extra parts."},{"question":"What compliance documentation is available?","answer":"Flame retardance meets UL 94 V1 and NF F 16-101/102. IP20 per VDE 0106. Shock and vibration per IEC 60068-2-27 and IEC 60068-2-6. Protective treatment per IEC 60068 and DIN 50016."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16017Q7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16017Q7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}