{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1601FC7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1601FC7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1601FC7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1601FC7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K1601FC7, 3P, AC-3 <=440 V 16 A, 1 NC, 127 V AC coil, IP20.","salesMarkdown":"The 127 V AC coil pulls in clean on standard control transformers. IP20 finger-safe terminals meet VDE 0106, which is fine inside a locked panel but not for open-belt exposure. ## Built for the pit — vibration and shock ratings that matter This reversing contactor shrugs off the vibration you get on a crusher floor or mill motor starter skid. Closed-contact shock rating hits 10 Gn on Y and Z axes, 15 Gn on X — that's a solid hit from a rock falling on the enclosure or a mill start transient. Vibration tested at 4 Gn closed, 5–300 Hz per IEC 60068-2-6. Open-contact ratings are lower (2 Gn vibration, 6 Gn shock on X) but that's the expected margin: you don't want contacts bouncing closed during a fault. The preassembled reversing busbar saves an hour of wiring and eliminates the risk of a mis-wired mechanical interlock. Three NO power poles handle the motor leads; the 1 NC auxiliary is built in for control logic feedback. The 127 V AC coil is common on North American control transformers with a 120 V secondary; verify your control voltage matches before committing the BOM line.","metaTitle":"TeSys K LC2K1601FC7 reversing contactor, 3P, 16 A, 127 V AC","metaDescription":"Active TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NC, 127 V AC coil. IP20, V1 flame retardance. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K1601FC7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NC, 127 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/141b06647dc379ae43df13e1a688edf2.pdf","sourceUrl":"https://www.se.com/in/en/product/LC2K1601FC7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-nc-127-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings for LC2K1601FC7?","answer":"AC-3 motor-switching rating is 16 A at <=440 V. Coil is 127 V AC. Three normally-open power poles plus one normally-closed auxiliary contact. IP20 finger-safe protection. Operating temperature range -25 to 50 °C."},{"question":"What compliance documentation does this part carry?","answer":"Flame retardance rated V1 per UL 94, plus NF F 16-101 and NF F 16-102 for rail applications. Protective treatment per IEC 60068 and DIN 50016. IP20 per VDE 0106. Shock and vibration tested per IEC 60068-2-27 and IEC 60068-2-6."},{"question":"What is the depth of LC2K1601FC7?","answer":"Listed depth is 57 mm. Overall dimensions are 90 mm wide by 58 mm high."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1601FC7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1601FC7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}