{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16105M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16105M7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16105M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16105M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K16105M7, 3P, AC-3 ≤440 V 16 A, 1 NO auxiliary, 220…230 V AC 50/60 Hz coil, preassembled with reversing power busbar, IP20 finger-safe.","salesMarkdown":"The Schneider Electric TeSys K LC2K16105M7 is a reversing contactor — three poles, preassembled with the reversing power busbar so you don't need to build the mechanical interlock and busbar stack yourself. It's rated for AC-3 duty at 16 A up to 440 V, with a 220…230 V AC 50/60 Hz coil. The headline AC-3 rating of 16 A at ≤440 V tells you this contactor handles motor full-load current up to that level. The coil pulls 220…230 V AC — common across European and Asian control circuits — and the contactor also carries an AC-4 utilisation category for plugging and inching duty, where the motor is reversed or stopped by counter-torque before it's at rest. The operating altitude of 2000 m without derating covers most installations; above that, you'd need to account for reduced air dielectric and cooling. ## Mechanical robustness and environment Rated for 10 Gn shocks on the Y and Z axes (contactor closed) and 4 Gn vibration at 5…300 Hz (contactor closed) per IEC 60068-2-27 and IEC 60068-2-6. That's enough for most industrial machinery — conveyors, pumps, compressors — but if your application sees sustained high-frequency vibration near the contactor's resonance band, you may want to check the opened-contactor limits (2 Gn vibration).","metaTitle":"Schneider TeSys K LC2K16105M7 reversing contactor, 3P, 16 A","metaDescription":"Schneider TeSys K reversing contactor LC2K16105M7, 3P, AC-3 ≤440 V 16 A, 1 NO, 220-230 VAC coil, preassembled with reversing busbar. Active production, IP20. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K16105M7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NO, 220...230 V AC","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/69d866d0e8badf9c5baa107c8c03edc8.pdf","sourceUrl":"https://www.se.com/in/en/product/LC2K16105M7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-220-230-v-ac/"},"ai":{"faq":[{"question":"What is the closest alternative to the LC2K16105M7 in the TeSys K family?","answer":"Within the TeSys K reversing contactor range, the main variant difference is the coil voltage. The LC2K16105M7 uses a 220…230 V AC coil. If your control voltage is different, the same 16 A AC-3 reversing contactor is available with other coil voltages (e.g., 24 V AC, 110 V AC, 380…400 V AC) under different order codes. The mechanical footprint and auxiliary contact arrangement are identical across the family."},{"question":"What is the depth of the LC2K16105M7?","answer":"The depth is 57 mm, with a width of 90 mm and height of 58 mm — fits a standard DIN-rail enclosure."},{"question":"What compliance documentation is available for the LC2K16105M7?","answer":"The contactor carries V1 flame retardance per UL 94, and conforms to NF F 16-101 and NF F 16-102 for rail applications. The IP20 rating is per VDE 0106. Standard Schneider Electric declarations (RoHS, REACH, CE, UKCA) apply to the TeSys K series; the specific product certificate and EU declaration of conformity are available from the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16105M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16105M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}