{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16105V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16105V7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16105V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16105V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 400 V AC coil, preassembled with reversing power busbar, IP20.","salesMarkdown":"The Schneider LC2K16105V7 is a TeSys K reversing contactor — a 3-pole, 3 NO main contact device rated for motor control in AC-3 and AC-4 duty. It's preassembled with a reversing power busbar, saving panel space and wiring time on a reversing starter build. Rated operational voltage on the power circuit is 690 V AC at 50/60 Hz, with the AC-3 switching current specified at 16 A up to 440 V. The coil is 400 V AC, so it pulls in directly from a 400 V line or control transformer without an intermediate relay.","metaTitle":"Schneider TeSys K LC2K16105V7 Reversing Contactor, 16 A, 400","metaDescription":"Obsolete Schneider TeSys K reversing contactor, 3P, AC-3 16 A at 440 V, 400 V AC coil. Sourced to order against RFQ. IP20, preassembled busbar.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b21e97f3fd3026e84a3fe1d5aee89047.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC2K16105V7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K16105V7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LC2K16105V7?","answer":"No official successor is listed. A parametric match from the current TeSys K or TeSys Deca range with the same coil voltage (400 V AC) and AC-3 rating (16 A at 440 V) would be the closest functional replacement, but pinout and busbar arrangement should be verified against the existing panel layout."},{"question":"What are the key ratings of LC2K16105V7?","answer":"It's a 3-pole reversing contactor rated AC-3 16 A at 440 V, with a 400 V AC coil. Power circuit rated 690 V AC 50/60 Hz. IP20 protection. Dimensions: 90 x 58 x 57 mm (W x H x D)."},{"question":"What compliance documentation does Schneider provide for LC2K16105V7?","answer":"The part carries flame retardance V1 per UL 94 and conforms to NF F 16-101 and NF F 16-102 (railway fire standards). Protective treatment conforms to IEC 60068 and DIN 50016. IP20 per VDE 0106. Shock and vibration ratings per IEC 60068-2-27 and IEC 60068-2-6 are listed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16105V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16105V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}