{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16107B72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16107B72","canonicalUrl":"https://aoctrl.com/schneider/LC2K16107B72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16107B72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K16107B72, 3P, AC-3 <=440 V 16 A, 1 NO, 24 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric TeSys K LC2K16107B72 is a reversing contactor — three poles, rated for AC-3 motor duty up to 16 A at 440 V, with a 24 V AC coil. It ships preassembled with the reversing power busbar, so you skip the separate busbar ordering and assembly step on the panel build. The AC-4 category also listed means it can handle plugging and inching duty, though that's harder on the contacts and you'd want to check cycle life against your application profile. No washdown rating here — keep it dry. The TeSys K family is broadly stocked, so this reversing contactor is a fast mover for maintenance spares and new panel builds alike. Keep one on the shelf if you have multiple machines using this form factor. ## Installation and environment notes The preassembled reversing busbar saves about 15 minutes of wiring per panel on a typical build. Flame retardance meets UL 94 V1 and NF F 16-101/102, which matters for rail and transit applications. Mechanical robustness is specified: closed contactor survives 10 Gn shocks on Y and Z axes, 6 Gn on X (11 ms half-sine). Vibration resistance at 4 Gn closed, 2 Gn open, 5–300 Hz. That's enough for most industrial machinery but not extreme off-road or marine engine mounts.","metaTitle":"TeSys K LC2K16107B72 Reversing Contactor, 3P, 16 A, 24 V AC","metaDescription":"TeSys K reversing contactor LC2K16107B72, 3P, AC-3 <=440 V 16 A, 24 V AC coil. Active production. IP20. Preassembled with reversing busbar. RFQ for pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K16107B72","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NO, 24 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e4e348c279e2dd8fc7224cd4bb914dda.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K16107B72/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-24-v-ac-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to LC2K16107B72 in the TeSys family?","answer":"Within the TeSys K range, the LC2K series reversing contactors share the same footprint and busbar arrangement. The main differentiator is the coil voltage — this unit uses 24 V AC. If your control voltage differs, the same mechanical assembly is available with other coil ratings. No pin-compatible drop-in from a different series exists without rewiring the busbar."},{"question":"What compliance documentation is available for LC2K16107B72?","answer":"The part carries IP20 per VDE 0106 and flame retardance V1 per UL 94, plus NF F 16-101/102 for rail fire-smoke-toxicity. Protective treatment conforms to IEC 60068 and DIN 50016. Standard Schneider declarations for RoHS and REACH are available through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16107B72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16107B72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}