{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16107C7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16107C7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16107C7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16107C7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 36 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"Rated AC-3 at 16 A up to 440 V, it handles reversing duty on three-phase induction motors in the 5.5–7.5 kW range (depending on line voltage and duty cycle). The coil is 36 V AC, which keeps control-circuit voltage low for operator safety in wet or metallic environments. IP20 finger-safe terminals per VDE 0106 mean it mounts inside a panel with no additional shrouding for basic touch protection. The AC-3 rating of 16 A at ≤440 V governs motor switching — that is the current the contactor can make and break under full-load motor start conditions (typically 6–8× FLC inrush). Operating altitude of 2000 m without derating covers most industrial sites; above that, air density drops and the contactor's arc-quenching margin narrows, so derate per IEC 60947-1.","metaTitle":"Schneider TeSys K LC2K16107C7 Reversing Contactor, 3P, 16A A","metaDescription":"Schneider Electric TeSys K reversing contactor LC2K16107C7. 3 poles, AC-3 rated 16A at ≤440V, 36V AC coil. Obsolete — sourced to order against RFQ. IP20, preassembled reversing bus","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2c954292fd9ccbe86ded75ae1d950453.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC2K16107C7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-36-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K16107C7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for LC2K16107C7?","answer":"Three poles, AC-3 utilisation category rated 16 A at ≤440 V AC, with a 36 V AC coil. IP20 finger-safe protection. Preassembled with reversing power busbar for direct motor reversal wiring."},{"question":"What is the closest alternative to LC2K16107C7 in the TeSys family?","answer":"There is no official direct replacement published under the TeSys K line. For new designs, the TeSys Deca or TeSys island ranges offer reversing contactors with similar pole counts and AC-3 ratings, but mounting footprint and wiring differ — expect a panel re-layout."},{"question":"What compliance documentation is available for LC2K16107C7?","answer":"The part carries UL 94 V1 flame retardance and NF F 16-101/102 compliance for rail applications. Standard Schneider documentation includes the product certificate and declaration of conformity; these are available through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16107C7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16107C7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}