{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16107D7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16107D7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16107D7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16107D7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 42 V AC coil, IP20, 90 x 58 x 57 mm.","salesMarkdown":"The 42 V AC coil keeps control circuit voltages low, common in panel designs where a separate control transformer steps down from line voltage. The 690 V AC rated operational voltage on the power circuit means the contactor can isolate higher-voltage lines, but the switching capacity at that voltage is derated from the 440 V figure. The 90 x 58 x 57 mm footprint fits standard DIN-rail or panel-mount layouts typical of TeSys K assemblies. ## Mechanical and environmental tolerance Rated for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6: the contactor holds closed under 10 Gn on Y and Z axes, and 4 Gn vibration closed across 5–300 Hz. That makes it suitable for equipment mounted on machinery or in transport applications where mechanical stress is a factor. Flame retardance meets V1 per UL 94 and NF F 16-101/102, relevant for rail and other fire-safety-regulated environments. Operating altitude is 2000 m without derating — above that, dielectric strength and thermal dissipation need to be reviewed per the manufacturer's application notes.","metaTitle":"Schneider TeSys K LC2K16107D7 Reversing Contactor, 16 A, 42","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 16 A at 440 V, 42 V AC coil. Sourced to order against RFQ. IP20, 90x58x57 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3da51524f861a06e478d8ebf4f4a79b.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K16107D7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-42-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K16107D7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"It is a 3-pole reversing contactor rated AC-3 16 A at ≤440 V, with a 42 V AC coil. The power circuit is rated for 690 V AC, and the enclosure is IP20 finger-safe. Dimensions are 90 mm wide, 58 mm high, 57 mm deep."},{"question":"What compliance documentation is available for the LC2K16107D7?","answer":"The contactor carries flame retardance ratings of V1 per UL 94 and meets NF F 16-101/102 requirements. It is also protective-treated per IEC 60068 and DIN 50016. The IP20 rating is per VDE 0106. Specific RoHS or REACH declarations would be part of the manufacturer's documentation set for the TeSys K series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16107D7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16107D7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}