{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16107J7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16107J7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16107J7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16107J7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3 poles, AC-3 ≤440 V 16 A, 1 NO auxiliary, 12 V AC coil, preassembled with reversing power busbar, IP20.","salesMarkdown":"The Schneider Electric LC2K16107J7 is a TeSys K reversing contactor — three poles, rated AC-3 at ≤440 V for 16 A motor switching, with a 12 V AC coil and one normally open auxiliary contact. It comes preassembled with the reversing power busbar, so you don't have to wire the mechanical interlock or main power crossover yourself; that's already done at the factory. The AC-3 rating is what matters here: it's built for starting and stopping squirrel-cage motors on the line, not just resistive loads. At 16 A on a 400 V three-phase supply, that covers motors up to roughly 7.5 kW (10 HP) — the kind you'd find on small conveyors, pumps, or fans in a control panel. The 12 V AC coil is an oddball in most modern panels that run 24 VDC or 120 VAC, so make sure your control transformer taps are set for it. At 90 mm wide by 58 mm deep by 57 mm tall, it's a compact block that fits in a crowded enclosure without hogging space. IP20 means it's finger-safe but not sealed; keep it inside a cabinet away from washdown or dust. Preassembled with the reversing busbar means you land your line and load wires directly on the power terminals — no extra bridging or interlock wiring. The 1 NO auxiliary can be used for a run-status signal back to the PLC or to seal in the coil circuit. Rated for vibration up to 4 Gn closed and shock up to 15 Gn on Y and Z axes, so it won't drop out on a shaky conveyor drive.","metaTitle":"Schneider Electric LC2K16107J7 TeSys K Reversing Contactor,","metaDescription":"Active-production TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 12 V AC coil. IP20, preassembled reversing busbar. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K16107J7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NO, 12 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9eb2141f17c70e80fdeee4f99ddec5a0.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K16107J7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-12-v-ac-coil/"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative to this contactor?","answer":"Within the TeSys K family, the LC2K series shares the same footprint and busbar arrangement. A direct functional alternative would be a same-frame reversing contactor with a different coil voltage — for example, the LC2K16107J7 uses 12 V AC; if your panel runs 24 V DC, you would look for the 24 V DC coil variant (LC2K1610BD or similar). The mechanical interlock and power busbar are identical across the series."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries V1 flame retardance per UL 94 and meets NF F 16-101/102 for railway fire-smoke-toxicity. It also conforms to IEC 60068 for shock and vibration. The standard Schneider declaration of conformity (CE, UKCA) and RoHS/REACH documentation are available from the manufacturer."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16107J7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16107J7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}