{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16107N7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16107N7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16107N7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16107N7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K16107N7, 3P, AC-3 <=440 V 16 A, 1 NO, 400...415 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"Three power poles, all normally open, with one auxiliary NO contact built in. AC-3 at 16 A tells you this contactor is sized for a motor load up to roughly 7.5 kW at 400 V — the standard induction motor starting current (6–8× FLC) is what AC-3 covers. The AC-4 category also listed means it's rated for plugging and inching duty, so it handles the occasional reverse-on-the-fly without derating. The coil is 400...415 V AC, which is common in European 400 V three-phase panels; if your control voltage is 230 V or 24 V DC, this coil won't pick up. ## Integration notes The preassembled reversing busbar means the two contactor halves are mechanically interlocked and the power bus is already linked; you just land the incoming line and outgoing motor leads. Flame retardance meets UL 94 V1 and NF F 16-101/102, which is typical for rail and industrial control panels.","metaTitle":"Schneider Electric LC2K16107N7 TeSys K Reversing Contactor,","metaDescription":"Schneider Electric LC2K16107N7 TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NO, 400-415 V AC coil. Active production. IP20. Preassembled busbar.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K16107N7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NO, 400...415 V AC","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/aafc18ef3abc46d98f1c2d10b31dd401.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K16107N7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-400-415-v-ac/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"Three poles, AC-3 rated 16 A at <=440 V, AC-4 rated for the same current. Coil voltage is 400...415 V AC 50/60 Hz. One built-in NO auxiliary contact. IP20 finger-safe. Preassembled with reversing power busbar."},{"question":"What compliance documentation is available for the LC2K16107N7?","answer":"Flame retardance is V1 per UL 94 and also meets NF F 16-101/102. Protective treatment conforms to IEC 60068 and DIN 50016. IP20 per VDE 0106. Shock and vibration ratings per IEC 60068-2-27 and IEC 60068-2-6 are listed in the spec table."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16107N7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16107N7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}