{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K16107R7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K16107R7","canonicalUrl":"https://aoctrl.com/schneider/LC2K16107R7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K16107R7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO auxiliary, 440 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric LC2K16107R7 is a TeSys K reversing contactor, 3-pole, rated 16 A in AC-3 utilisation category at ≤440 V with a 440 V AC coil. It comes preassembled with the reversing power busbar, so you don't have to wire the mechanical and electrical interlock yourself — it's a drop-in reversing starter for a three-phase motor up to that current. That's the number that governs real motor control applications — not the AC-1 resistive rating. ## Mechanical and environmental robustness Rated for 10 Gn shock on Y and Z axes (contactor closed) and 15 Gn on Y and Z (contactor opened), per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn opened across 5–300 Hz. That's enough for most industrial machinery and mobile equipment applications, including conveyors, pumps, and compressors mounted on a machine frame. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance — relevant for humid or mildly aggressive atmospheres in food-and-bev or wastewater plants.","metaTitle":"Schneider TeSys K LC2K16107R7 Reversing Contactor, 3P, 16 A","metaDescription":"TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NO, 440 V AC coil. Active production. IP20. Preassembled with reversing busbar. Source to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K16107R7","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NO, 440 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ef1a7d8e41988c4a2cbd4ff2e2deea61.pdf","sourceUrl":"https://www.se.com/in/en/product/LC2K16107R7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-440-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"It is a 3-pole reversing contactor rated 16 A in AC-3 duty at ≤440 V, with a 440 V AC coil. It includes one normally-open auxiliary contact and comes preassembled with the reversing power busbar."},{"question":"What is the closest alternative to the LC2K16107R7 in the TeSys K family?","answer":"Within the same TeSys K series, the non-reversing equivalent is the LC1K16107R7 — same coil voltage, same 16 A AC-3 rating, but without the reversing busbar or mechanical interlock. For a reversing application, the LC2K16107R7 is the pre-assembled solution; you would otherwise need two LC1K contactors plus a separate mechanical interlock (LA9K) and busbar kit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K16107R7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K16107R7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}