{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1610B7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1610B7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1610B7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1610B7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K series, reversing contactor LC2K1610B7, 3 poles, AC-3/AC-3e 16A at ≤440V, 1NO auxiliary contact, 24V AC coil, IP20.","salesMarkdown":"## Part identity and what it does The 1NO auxiliary contact gives you one feedback or interlock signal without adding a side-mount block. AC-3e extends the rating to energy-efficient motors with higher inrush. The 24 V AC coil is common in older control transformers; verify your control voltage matches because AC coils draw higher inrush than DC and won't pick below about 20 V. Rated for -25 to 50 °C ambient operation and -50 to 80 °C storage. The contactor holds closed through 10 Gn shocks on Y and Z axes, 6 Gn on X when open — enough for most industrial panel environments. V1 flame retardance per UL 94 and NF F 16-101/102 covers rail and industrial fire-safety requirements. Altitude derating starts above 2000 m. The contactor measures 90 mm wide by 58 mm high by 57 mm deep. The preassembled reversing busbar saves panel space compared to wiring two separate contactors with an interlock, but the 90 mm width means you need that much rail per reversing pair. The 3 NO power poles are all main contacts; no built-in NC for mechanical interlock — that's handled by the busbar and the contactor's own interlock mechanism.","metaTitle":"TeSys K LC2K1610B7 Reversing Contactor, 16A AC-3, 24V AC Coi","metaDescription":"LC2K1610B7 reversing contactor, TeSys K series, 3P, AC-3/AC-3e 16A at <=440V, 1NO aux, 24V AC coil. Active production. IP20. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K1610B7","Height":"58 mm","description":"Reversing contactor, TeSys K, 3P, AC-3/AC-3e,<= 440V 16A, 1NO, 24V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-3e AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$144.88","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5db513ea93c5d62851df2be34860cdc5.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K1610B7/reversing-contactor-tesys-k-3p-ac3-ac3e-440v-16a-1no-24v-ac-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to the LC2K1610B7 in the TeSys K family?","answer":"Within the TeSys K family, the closest alternative would be a reversing contactor with a different coil voltage — for example, the LC2K1610B7 uses a 24 V AC coil, while variants with 48 V AC, 110 V AC, or 24 V DC coils exist. The power pole rating (16 A AC-3) and the 1NO auxiliary contact remain the same across those variants. No pin-compatible drop-in with a different rating exists within the same frame size."},{"question":"What is the depth of the LC2K1610B7?","answer":"The LC2K1610B7 has a depth of 57 mm. Combined with its 90 mm width and 58 mm height, it fits a standard DIN-rail footprint with a 35 mm rail clip."},{"question":"What compliance documentation does Schneider provide for the LC2K1610B7?","answer":"The LC2K1610B7 carries V1 flame retardance per UL 94, plus compliance with NF F 16-101 and NF F 16-102 for rail fire safety. It meets IEC 60068 for shock and vibration, and IEC 60068-2-27 for mechanical robustness. The protective treatment conforms to IEC 60068 and DIN 50016. Full RoHS, REACH, and CE declarations are available from Schneider Electric's documentation portal for the TeSys K series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1610B7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1610B7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}