{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1610FC72","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1610FC72","canonicalUrl":"https://aoctrl.com/schneider/LC2K1610FC72","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1610FC72","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <=440 V 16 A, 1 NO, 127 V AC coil, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric LC2K1610FC72 is a TeSys K reversing contactor — a 3-pole, 3 NO power pole unit rated for AC-3 duty at 16 A up to 440 V, with a 127 V AC coil and one built-in NO auxiliary contact. It ships preassembled with the reversing power busbar, so you skip the mechanical interlock wiring and busbar assembly step on the panel bench. The AC-4 rating covers plugging and inching duty, where the contactor breaks stalled-rotor current. For a reversing pair, AC-4 is the tougher cycle; this contactor carries both categories. The coil pulls 127 V AC — common in North American control transformers and older European panels. IP20 finger-safe terminals per VDE 0106 keep the panel builder out of trouble during commissioning. The protective treatment (TC per IEC 60068 and DIN 50016) indicates the contactor has passed a damp-heat cyclic test — relevant if the panel sees condensation or high-humidity environments. No special coating or conformal coating is listed beyond this standard treatment.","metaTitle":"Schneider TeSys K LC2K1610FC72 reversing contactor, 16 A, 12","metaDescription":"Schneider TeSys K reversing contactor LC2K1610FC72, 3P, AC-3 <=440 V 16 A, 1 NO, 127 V AC coil. Active production. IP20. Preassembled with reversing busbar. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LC2K1610FC72","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 16 A, 1 NO, 127 V AC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e94033f9384786eb39fa398234a78c7b.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC2K1610FC72/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-127-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key ratings I need to check for fit?","answer":"The headline rating is AC-3 <=440 V at 16 A for motor switching. The coil is 127 V AC. Power circuit rated operational voltage is 690 V AC 50/60 Hz. It has one NO auxiliary contact built in. Dimensions: 90 mm wide, 58 mm tall, 57 mm deep."},{"question":"Does this reversing contactor come with the busbar preassembled?","answer":"Yes, the device presentation is 'Preassembled with reversing power busbar'. That means the mechanical interlock and the power busbar linking the two contactors are already fitted — you mount it as one unit on the DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1610FC72","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1610FC72 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}