{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC2K1610V7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC2K1610V7","canonicalUrl":"https://aoctrl.com/schneider/LC2K1610V7","factsUrl":"https://aoctrl.com/api/mcp/products/LC2K1610V7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LC2K1610V7, 3P, AC-3 ≤440 V 16 A, 1 NO, 400 V AC coil, IP20.","salesMarkdown":"The AC-3 16 A rating at ≤440 V governs motor switching: it is the current the contactor can make and break under full-load motor start conditions. For a 400 V three-phase motor, that translates to roughly 7.5 kW (10 HP) — enough for a small conveyor or pump. The AC-4 rating, while not quantified here, tells you the contactor is designed for the higher arc erosion of reversing and jogging, not just steady running. The 400 V AC coil is a specific control voltage — not 230 V, not 24 VDC. If your control circuit runs 400 V line-to-line, this coil matches directly. If your panel uses a lower control voltage, you need a different coil variant in the TeSys K family. Mechanical shock and vibration ratings (10 Gn on Y/Z axis closed, 4 Gn vibration closed per IEC 60068-2-27/6) mean it holds in on rail or mobile equipment without dropping out. The preassembled reversing busbar saves panel wiring time but fixes the pole arrangement; you cannot reconfigure it in the field.","metaTitle":"TeSys K LC2K1610V7 Reversing Contactor, 16 A, 400 V AC Coil","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 ≤440 V 16 A, 1 NO, 400 V AC coil. Sourced to order against RFQ. IP20, V1 flame retardance.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LC2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1333f20c75bc204efbfff53c58810d13.pdf","sourceUrl":"https://www.se.com/mk/en/product/LC2K1610V7/tesys-k-reversing-contactor-3p-ac3-440-v-16-a-1-no-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC2K1610V7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 3-pole reversing contactor rated AC-3 ≤440 V 16 A, with a 400 V AC coil and one normally-open auxiliary contact. IP20 protected, V1 flame retardance, operating temperature -25 to 50 °C."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The contactor carries a V1 flame-retardance rating conforming to UL 94, NF F 16-101, and NF F 16-102. It also meets IEC 60068 for shock and vibration, and IEC 60068 for protective treatment (TC). No RoHS or REACH statements are in the record."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC2K1610V7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC2K1610V7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}