{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC3D115P7A64","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC3D115P7A64","canonicalUrl":"https://aoctrl.com/schneider/LC3D115P7A64","factsUrl":"https://aoctrl.com/api/mcp/products/LC3D115P7A64","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LC3D115P7A64 pre-wired star-delta starter, 3×3P NO, AC-3 utilisation, 575 VAC, 110 kW rating.","salesMarkdown":"The LC3D115P7A64 is a pre-wired TeSys Deca star-delta starter, rated for AC-3 motor-switching duty with 3×3P NO contacts, and now obsolete per Schneider. No direct replacement listed under TeSys Deca; source through surplus. AC-3 utilisation means the contactor is designed for switching squirrel-cage motors: making and breaking currents up to several times the rated operational current. The 3×3P configuration (three NO power poles per phase) is specific to star-delta starting, reducing inrush on transition. Pollution degree 3 and IP20 front face (IEC 60529) indicate the device is intended for an industrial enclosure where conductive dust or occasional condensation may occur. TH protective treatment (IEC 60068-2-30) confirms it withstands damp heat cycles. Flame retardance V1 (UL 94) and fire resistance at 850°C (IEC 60695-2-1) are relevant for panel certification — no additional fuse or barrier needed for these aspects. This star-delta starter is wired into MCCs or standalone panels for starting three-phase induction motors. The pre-wired format reduces field wiring time. Operating altitude is rated to 3000 m without derating; ambient operation from -40 to 60°C, with derating up to 70°C. ## Sourcing & lifecycle reality The LC3D115P7A64 is obsolete per Schneider. No direct replacement from Schneider has been recorded; verify any claimed equivalent by checking the nameplate and wiring scheme. Source through surplus or submit an RFQ for availability and lead time.","metaTitle":"Schneider LC3D115P7A64 TeSys Deca Star-Delta Starter, Obsole","metaDescription":"LC3D115P7A64 TeSys Deca star-delta starter, 575VAC, 110kW, 3x3P AC-3. Now obsolete; sourced to order via surplus channels. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Unclassified"],"specifications":{"Range":"TeSys","Category":"US10I1222359","Product name":"TeSys Deca","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Pollution degree":"3","Device short name":"LC3D","Poles description":"3 x 3P","Operating altitude":"9842.52 ft (3000 m)","Device presentation":"Pre-wired","Protective treatment":"TH IEC 60068-2-30","Utilisation category":"AC-3","Contactor application":"Motor control","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Vibrations contactor closed4 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Shocks contactor open6 Gn for 11 ms","Nbr. of units in pkg.":"1","IP degree of protection":"IP20 front face IEC 60529","Product or Component Type":"Star delta starter","Power Pole Contact Composition":"3 x 3 NO","[Ue] rated operational voltage":"Power circuit 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/70ad4a5fc0268f90a683cfde4c947eac.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LC3D115P7A64/alternatives.json"},"ai":{"faq":[{"question":"What is the range and series of this starter?","answer":"It belongs to the TeSys range and the TeSys Deca product family."},{"question":"What compliance documentation is available for this part?","answer":"The device meets IEC 60695-2-1 fire resistance (850°C), UL 94 V1 flame retardance, IP20 protection (IEC 60529), and TH protective treatment per IEC 60068-2-30. RoHS/REACH status is not listed in available data."},{"question":"How should I source this obsolete starter?","answer":"Since it is no longer manufactured, sourcing is through surplus and broker channels. Submit an RFQ to confirm stock and lead time from our supply network."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC3D115P7A64","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC3D115P7A64 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}