{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC3F265F7A64","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC3F265F7A64","canonicalUrl":"https://aoctrl.com/schneider/LC3F265F7A64","factsUrl":"https://aoctrl.com/api/mcp/products/LC3F265F7A64","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC3F265F7A64, pre-wired star-delta starter, 3 x 3P, 110 V AC 50/60 Hz coil, AC-3 utilisation category, motor power up to 250 kW at 440 V.","salesMarkdown":"## Product Identification and Compliance It is a 3 x 3P device (three power poles, each with three normally-open contacts) with a 110 V AC 50/60 Hz control coil. Per the specification, it is rated for motor power up to 110 kW at 220/230 V, 220 kW at 380/400 V and 415 V, and 250 kW at 440 V, all at 50/60 Hz. This unit is fully compliant with IEC 60947-4-1, IEC 60947-1, EN 60947-1, JIS C8201-4-1, and EN 60947-4-1, providing a defensible basis for specification in tender submissions. ## Key Ratings and Performance Characteristics The AC-3 utilisation category rating means this starter is specifically rated for starting squirrel-cage motors and switching them off during running — the standard duty for motor control. The rated insulation voltage (Ui) is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C, giving headroom for 690 V systems. The rated breaking capacity is 2120 A and the rated making capacity is 2650 A, both conforming to IEC 60947-4-1, which defines the fault-clearing and inrush-handling capability respectively. The associated fuse recommendation is 400 A gG or 315 A aM up to 440 V — this is the coordination point for short-circuit protection and must be respected for Type 2 coordination. ## Control Circuit and Auxiliary Contacts The control circuit operates on 110 V AC 50/60 Hz with an operational voltage range of 0.85 to 1.1 Uc and a drop-out range of 0.35 to 0.55 Uc. Inrush power is 650 VA at 40-400 Hz, cos φ 0.9 at 20 °C. The auxiliary contact composition is factory-configured for star-delta operation: 1 NC and 1 NO on the star contactor (KM1), 2 NC and 1 NO on the line contactor (KM2), and 1 NC and 2 NO on the delta contactor (KM3). The mechanical interlock between the star and delta contactors is integral — this prevents simultaneous closure, a mandatory safety requirement for star-delta starting. ## Mechanical and Environmental Specifications The unit is mechanically robust: it withstands vibrations of 2 Gn at 5-300 Hz when open and 5 Gn at 5-300 Hz when closed, and shocks of 15 Gn for 11 ms when closed and 6 Gn for 11 ms when open. The front face with shrouds provides IP20 protection per IEC 60529 and VDE 0106. Protective treatment is TH (tropicalized) for humid environments. Heat dissipation is 8 W. ## Mounting and Connection Details Mounting is plate-mount — not DIN rail — so panel layout must allocate a dedicated mounting surface. Dimensions are 10.5 in (266 mm) depth, 24.6 in (625 mm) width, and 4.3 in (110 mm) height. Power circuit connections use bolted lugs or ring terminals up to 240 mm², with a bolt diameter of M10 and a tightening torque of 309.8 lbf·in (35 N·m). Control circuit connections use screw clamp terminals accepting 1 to 4 mm² flexible with or without cable end, or solid wire. The unit is pre-wired, reducing field wiring time for the star-delta configuration.","metaTitle":"Schneider Electric LC3F265F7A64 TeSys F Star-Delta Starter,","metaDescription":"Schneider Electric LC3F265F7A64 TeSys F star-delta starter. AC-3 motor control up to 250 kW at 440 V. 110 VAC 50/60 Hz coil. IEC 60947-4-1 compliant. Current production status. Sou","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"10.5 in (266 mm)","Range":"TeSys","Width":"24.6 in (625 mm)","Height":"4.3 in (110 mm)","Category":"18401-WORLD SERVICE PARTS(CTR ACCESS)","Standards":"IEC 60947-4-1 IEC 60947-1 EN 60947-1 JIS C8201-4-1 EN 60947-4-1","Product name":"TeSys F","Starting time":"30 s","Motor power kW":"110 kW 220/230 V AC 50/60 Hz 220 kW 380/400 V AC 50/60 Hz 220 kW 415 V AC 50/60 Hz 250 kW 440 V AC 50/60 Hz","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"current","Heat dissipation":"8 W","Mounting Support":"Plate","Device short name":"LC3F","Interlocking type":"Mechanical","Poles description":"3 x 3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)","Inrush power in VA":"650 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))","Operating altitude":"9842.52 ft (3000 m) without derating","Device presentation":"Pre-wired","Control circuit type":"AC 50/60 Hz","Protective treatment":"TH","Utilisation category":"AC-3","Contactor application":"Motor control","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open6 Gn for 11 ms","Nbr. of units in pkg.":"1","Associated fuse rating":"400 A gG 315 A aM <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Power circuit: bar 2 - busbar cross section: 32 x 4 mm Power circuit: bolted connection Power circuit: lugs-ring terminals 1 0.4 in² (240 mm²) Power circuit: connector 1 0.4 in² (240 mm²)","IP degree of protection":"IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106","Rated breaking capacity":"2120 A conforming to IEC 60947-4-1","Connections Bolt Diameter":"M10","Product or Component Type":"Star delta starter","Irms rated making capacity":"2650 A IEC 60947-4-1","[Uc] control circuit voltage":"110 V AC 50/60 Hz","Auxiliary contact composition":"1 NC KM1 star contactor 1 NO KM1 star contactor 2 NC KM2 line contactor 1 NO KM2 line contactor 1 NC KM3 delta contactor 2 NO KM3 delta contactor","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc at 40...400 Hz (at Drop-out: 0.35...0.55 Uc at 40...400 Hz (at <131 °F (55 °C))","Power Pole Contact Composition":"3 x 3 NO","[Ie] rated operational current":"265 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 for power circuit","[Ue] rated operational voltage":"Power circuit <= 1000 V AC 16 Hz 2/3...200 Hz","Hold-in power consumption in VA":"10 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"23...131 °F (-5...55 °C) -40...158 °F (-40...70 °C) at Uc","[Uimp] rated impulse withstand voltage":"8 kV coil not connected to the power circuit","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"350 A 104 °F (40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6745ccf19186a062cbe4ef2eb8309959.pdf","sourceUrl":"https://www.se.com/us/en/product/LC3F265F7A64/tesys-f-star-delta-starter-3-x-3p-3-no-265-a-110-v-ac-coilmech-interlock/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC3F265F7A64/alternatives.json"},"ai":{"faq":[{"question":"What are the key motor power ratings for this star-delta starter?","answer":"The LC3F265F7A64 is rated for motor power up to 110 kW at 220/230 V AC, 220 kW at 380/400 V and 415 V AC, and 250 kW at 440 V AC, all at 50/60 Hz, in AC-3 duty."},{"question":"What compliance standards does this unit meet?","answer":"It is fully compliant with IEC 60947-4-1, IEC 60947-1, EN 60947-1, JIS C8201-4-1, and EN 60947-4-1, providing a defensible specification basis for tender submissions."},{"question":"What is the control voltage and coil type?","answer":"The control circuit operates on 110 V AC at 50/60 Hz, with an operational range of 0.85 to 1.1 Uc and a drop-out range of 0.35 to 0.55 Uc."},{"question":"What are the physical dimensions of this unit?","answer":"The dimensions are 10.5 in (266 mm) depth, 24.6 in (625 mm) width, and 4.3 in (110 mm) height. It is plate-mount, not DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC3F265F7A64","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC3F265F7A64 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}