{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC3F265FE7A64","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC3F265FE7A64","canonicalUrl":"https://aoctrl.com/schneider/LC3F265FE7A64","factsUrl":"https://aoctrl.com/api/mcp/products/LC3F265FE7A64","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC3F265FE7A64, pre-wired star delta starter, 265 A AC-3 at ≤440 V, 115 V AC 50/60 Hz coil, plate mount.","salesMarkdown":"The Schneider Electric LC3F265FE7A64 is a pre-wired TeSys F star delta starter, built for motor control in the AC-3 utilisation category. It's rated for 265 A operational current at ≤440 V AC, which means it handles the inrush and run current of a motor started star-delta — the 265 A figure is the line current during delta-run, not the start. Motor power capability reaches 220 kW at 380/400 V AC and 250 kW at 440 V AC. The control circuit is 115 V AC at 50/60 Hz, with an operational voltage window of 0.85 to 1.1 Uc and a drop-out range of 0.35 to 0.55 Uc. Coil inrush is 650 VA at 40–400 Hz, cos φ 0.9 at 20 °C. Closing time runs 40–65 ms; opening is 100–170 ms. That's a deliberate delay — the star-to-delta transition needs the opening time to ensure the star contactor drops before the delta contactor picks up. Plate-mounted, not DIN rail. The footprint is 625 mm wide × 110 mm high × 266 mm deep — that's a substantial assembly, sized for the three contactors (star, line, delta) and the interlocking mechanism. Power connections use M10 bolts, bar or lug terminals up to 240 mm². Control wiring is screw clamp, accepting 1 to 4 mm² flexible or solid. Tightening torque is 35 N·m on the power circuit, 1.2 N·m on control. The auxiliary contact complement is already wired in: 1 NC + 1 NO on the star contactor (KM1), 2 NC + 1 NO on the line contactor (KM2), and 1 NC + 2 NO on the delta contactor (KM3). That covers the interlocking and signalling for a standard star-delta sequence without adding external auxiliaries. Mechanical interlocking between the star and delta contactors is built in. Designed and tested to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1, 1500 V per VDE 0110 group C. Breaking capacity is 2120 A; making capacity is 2650 A, both conforming to IEC 60947-4-1. Front face carries IP20 protection with shrouds fitted, per IEC 60529 and VDE 0106.","metaTitle":"Schneider Electric LC3F265FE7A64 TeSys F Star Delta Starter,","metaDescription":"Schneider Electric LC3F265FE7A64 TeSys F star delta starter. 265 A rated operational current (AC-3) at ≤440 V. 115 V AC coil. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"266 mm","Range":"TeSys","Width":"625 mm","Height":"110 mm","Standards":"IEC 60947-4-1 EN 60947-1 EN 60947-4-1 IEC 60947-1 JIS C8201-4-1","Product name":"TeSys F","Starting time":"30 s","Motor power kW":"110 kW at 220/230 V AC 50/60 Hz 220 kW at 380/400 V AC 50/60 Hz 220 kW at 415 V AC 50/60 Hz 250 kW at 440 V AC 50/60 Hz","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"current","Heat dissipation":"8 W","Mounting support":"Plate","Device short name":"LC3F","Interlocking type":"Mechanical","Poles description":"3 x 3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Inrush power in VA":"650 VA 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Device presentation":"Pre-wired","Control circuit type":"AC at 50/60 Hz","Protective treatment":"TH","Utilisation category":"AC-3","Contactor application":"Motor control","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms","Associated fuse rating":"400 A gG at 315 A aM at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end Power circuit: bar 2 - busbar cross section: 32 x 4 mm Power circuit: bolted connection Power circuit: lugs-ring terminals 1 240 mm² Power circuit: connector 1 240 mm²","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"2120 A conforming to IEC 60947-4-1","Connections Bolt Diameter":"M10","Product or component type":"Star delta starter","Irms rated making capacity":"2650 A conforming to IEC 60947-4-1","[Uc] control circuit voltage":"115 V AC 50/60 Hz","Auxiliary contact composition":"1 NC for KM1 star contactor 1 NO for KM1 star contactor 2 NC for KM2 line contactor 1 NO for KM2 line contactor 1 NC for KM3 delta contactor 2 NO for KM3 delta contactor","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc at 40...400 Hz (at Drop-out: 0.35...0.55 Uc at 40...400 Hz (at <55 °C)","Power Pole Contact Composition":"3 x 3 NO","[Ie] rated operational current":"265 A (at <55 °C) at <= 440 V AC AC-3 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz","Hold-in power consumption in VA":"10 VA 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C -40...70 °C at Uc","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 40 °C - 10 s 1230 A 40 °C - 30 s 950 A 40 °C - 1 min 620 A 40 °C - 3 min 480 A 40 °C - 10 min","[Ith] conventional free air thermal current":"350 A 40 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c74210a8d337a361d6c8ff23bbf3561c.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC3F265FE7A64/tesys-f-star-delta-starter-3-x-3p-3-no-265-a-115-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC3F265FE7A64/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this star delta starter?","answer":"Rated operational current is 265 A in AC-3 at ≤440 V AC. Motor power reaches 220 kW at 380/400 V and 250 kW at 440 V. Control circuit is 115 V AC 50/60 Hz. Mechanical durability is 10 million cycles."},{"question":"What compliance documentation is available for this part?","answer":"The part is designed to IEC 60947-4-1, EN 60947-4-1, IEC 60947-1, EN 60947-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Front face IP20 per IEC 60529 and VDE 0106."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC3F265FE7A64","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC3F265FE7A64 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}