{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC3F265M7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC3F265M7","canonicalUrl":"https://aoctrl.com/schneider/LC3F265M7","factsUrl":"https://aoctrl.com/api/mcp/products/LC3F265M7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F star delta starter, LC3F265M7, 3 x 3P, AC-3, 110-250 kW motor power, 220/230 V AC 50/60 Hz coil.","salesMarkdown":"It switches three-phase induction motors from 110 kW at 220/230 V up to 250 kW at 440 V, making it a direct fit for medium-to-large pump, fan, and compressor applications where reduced inrush current during start-up is required. The 220/230 V AC 50/60 Hz control circuit pulls 650 VA inrush at 20 °C; the coil holds at 0.85 to 1.1 Uc and drops out between 0.35 and 0.55 Uc. The unit is rated for 1000 V insulation (IEC 60947-4-1) and 1500 V per VDE 0110 group C, with a breaking capacity of 2120 A and making capacity of 2650 A per IEC 60947-4-1. Associated fuse protection is 400 A gG or 315 A aM up to 440 V. Mounts on a plate (not DIN rail), with bolted power connections via M10 bolts or ring terminals up to 240 mm². The power circuit uses bar connections with a 32 x 4 mm busbar cross-section. Control wiring uses screw clamp terminals accepting 1 to 4 mm² flexible or solid conductors. The front face achieves IP20 with shrouds per IEC 60529 and VDE 0106.","metaTitle":"Schneider LC3F265M7 TeSys F Star Delta Starter, 110-250 kW,","metaDescription":"Schneider Electric LC3F265M7 TeSys F star delta starter, 110-250 kW motor power, AC-3, 220/230 V AC coil. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"10.5 in (266 mm)","Range":"TeSys","Width":"24.6 in (625 mm)","Height":"4.3 in (110 mm)","Category":"22336-CTR,F-LINE,AC,OPEN,NONREV","Standards":"EN 60947-4-1 IEC 60947-4-1 JIS C8201-4-1 IEC 60947-1 EN 60947-1","Product name":"TeSys F","Starting time":"20 s","Motor power kW":"110 kW 220/230 V AC 50/60 Hz 220 kW 380/400 V AC 50/60 Hz 220 kW 415 V AC 50/60 Hz 250 kW 440 V AC 50/60 Hz","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"current","Heat dissipation":"8 W","Mounting Support":"Plate","Device short name":"LC3F","Interlocking type":"Without start delta mechanical interlock","Poles description":"3 x 3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)","Inrush power in VA":"650 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))","Operating altitude":"9842.52 ft (3000 m) without derating","Device presentation":"Pre-wired","Control circuit type":"AC 50/60 Hz","Protective treatment":"TH","Utilisation category":"AC-3","Contactor application":"Motor control","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open6 Gn for 11 ms","Nbr. of units in pkg.":"1","Associated fuse rating":"400 A gG 315 A aM <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Power circuit: bar 2 - busbar cross section: 32 x 4 mm Power circuit: bolted connection Power circuit: lugs-ring terminals 1 0.4 in² (240 mm²) Power circuit: connector 1 0.4 in² (240 mm²)","IP degree of protection":"IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106","Rated breaking capacity":"2120 A conforming to IEC 60947-4-1","Connections Bolt Diameter":"M10","Product or Component Type":"Star delta starter","Irms rated making capacity":"2650 A IEC 60947-4-1","[Uc] control circuit voltage":"220/230 V AC 50/60 Hz","Auxiliary contact composition":"1 NC KM1 star contactor 1 NO KM1 star contactor 2 NC KM2 line contactor 1 NO KM2 line contactor 1 NC KM3 delta contactor 2 NO KM3 delta contactor","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc at 40...400 Hz (at Drop-out: 0.35...0.55 Uc at 40...400 Hz (at <131 °F (55 °C))","Power Pole Contact Composition":"3 x 3 NO","[Ie] rated operational current":"265 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 for power circuit","[Ue] rated operational voltage":"Power circuit <= 1000 V AC 16 Hz 2/3...200 Hz","Hold-in power consumption in VA":"10 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"23...131 °F (-5...55 °C) -40...158 °F (-40...70 °C) at Uc","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"350 A 104 °F (40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e53f5da8c81d133312ebab7d709205d1.pdf","sourceUrl":"https://www.se.com/sg/en/product/LC3F265M7/tesys-f-star-delta-starter-3-x-3p-3-no-265-a-220-230-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC3F265M7/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LC3F265M7?","answer":"It is a star delta starter rated for AC-3 motor control, with motor power from 110 kW at 220/230 V to 250 kW at 440 V. The control circuit is 220/230 V AC 50/60 Hz, and the unit has a mechanical durability of 10 million cycles."},{"question":"What standards does the LC3F265M7 comply with?","answer":"It complies with EN 60947-4-1, IEC 60947-4-1, JIS C8201-4-1, IEC 60947-1, and EN 60947-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC3F265M7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC3F265M7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}