{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC3F265M7A64","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC3F265M7A64","canonicalUrl":"https://aoctrl.com/schneider/LC3F265M7A64","factsUrl":"https://aoctrl.com/api/mcp/products/LC3F265M7A64","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC3F265M7A64, pre-wired star delta starter, AC-3, 110 kW at 220/230 V AC, plate mount.","salesMarkdown":"The Schneider Electric TeSys F LC3F265M7A64 is a pre-wired star delta starter designed for motor control applications. It is rated for AC-3 utilisation category, meaning it is built for switching squirrel-cage motors — making and breaking stalled-rotor currents during starting and stopping. The unit integrates three contactors (line, star, delta) with a mechanical interlock, so the star and delta contactors cannot close simultaneously, which is the fundamental requirement for any star-delta transition. The power circuit uses a 3 x 3 NO pole configuration, with power connections via bolted lugs or bars accepting up to 240 mm² cable. Control circuit voltage is 220/230 V AC at 50/60 Hz, with an inrush of 650 VA at cos φ 0.9. The control circuit operates between 0.85 and 1.1 Uc for pick-up and drops out between 0.35 and 0.55 Uc. This is a plate-mounted assembly, not a DIN-rail unit — plan for a backplate or sub-panel in the enclosure. Motor power ratings are given per voltage: 110 kW at 220/230 V AC, 220 kW at 380/400 V AC, 220 kW at 415 V AC, and 250 kW at 440 V AC. These are the maximum three-phase induction motor loads the starter can handle at those line voltages. The rated breaking capacity is 2120 A per IEC 60947-4-1, and the rated making capacity is 2650 A — these numbers govern the starter's ability to interrupt a fault or close onto a short, so they set the expectations for upstream protection coordination. Associated fuse ratings are 400 A gG or 315 A aM at voltages up to 440 V. This is the maximum fuse size for type-2 coordination — exceed it and you risk the starter welding closed on a fault. Heat dissipation is 8 W, which is negligible for panel thermal calculations but worth noting if the enclosure is densely packed. The starter is designed and tested to EN 60947-4-1, IEC 60947-4-1, EN 60947-1, IEC 60947-1, and JIS C8201-4-1. These standards cover the performance and safety requirements for contactors and motor-starters. The rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C, so the internal clearances and creepage distances are sized for 690 V systems with margin.","metaTitle":"Schneider Electric LC3F265M7A64 TeSys F Star Delta Starter,","metaDescription":"Schneider Electric TeSys F LC3F265M7A64 star delta starter. AC-3 rated for 110 kW at 220/230 V AC. Current lifecycle stage. Pre-wired with mechanical interlock. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"10.5 in (266 mm)","Range":"TeSys","Width":"24.6 in (625 mm)","title":"LC3F265M7A64","Height":"4.3 in (110 mm)","Category":"18401-WORLD SERVICE PARTS(CTR ACCESS)","Standards":"EN 60947-4-1 EN 60947-1 IEC 60947-4-1 IEC 60947-1 JIS C8201-4-1","description":"TeSys F - star delta starter - 3 x 3P (3 NO) - 265 A - 220/230 V AC coil","Product name":"TeSys F","Starting time":"30 s","Motor power kW":"110 kW 220/230 V AC 50/60 Hz 220 kW 380/400 V AC 50/60 Hz 220 kW 415 V AC 50/60 Hz 250 kW 440 V AC 50/60 Hz","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"current","Heat dissipation":"8 W","Mounting Support":"Plate","Device short name":"LC3F","Interlocking type":"Mechanical","Poles description":"3 x 3P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 309.8 lbf.in (35 N.m)","Inrush power in VA":"650 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))","Operating altitude":"9842.52 ft (3000 m) without derating","Device presentation":"Pre-wired","Control circuit type":"AC 50/60 Hz","Protective treatment":"TH","Utilisation category":"AC-3","Contactor application":"Motor control","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open2 Gn, 5...300 Hz Shocks contactor closed15 Gn for 11 ms Vibrations contactor closed5 Gn, 5...300 Hz Shocks contactor open6 Gn for 11 ms","Nbr. of units in pkg.":"1","Associated fuse rating":"400 A gG 315 A aM <= 440 V","Maximum operating rate":"2400 cyc/h 131 °F (55 °C)","Connections - terminals":"Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid without cable end Power circuit: bar 2 - busbar cross section: 32 x 4 mm Power circuit: bolted connection Power circuit: lugs-ring terminals 1 0.4 in² (240 mm²) Power circuit: connector 1 0.4 in² (240 mm²)","IP degree of protection":"IP20 front face with shrouds IEC 60529 IP20 front face with shrouds VDE 0106","Rated breaking capacity":"2120 A conforming to IEC 60947-4-1","Connections Bolt Diameter":"M10","Product or Component Type":"Star delta starter","Irms rated making capacity":"2650 A IEC 60947-4-1","[Uc] control circuit voltage":"220/230 V AC 50/60 Hz","Auxiliary contact composition":"1 NC KM1 star contactor 1 NO KM1 star contactor 2 NC KM2 line contactor 1 NO KM2 line contactor 1 NC KM3 delta contactor 2 NO KM3 delta contactor","[Ui] rated insulation voltage":"1000 V IEC 60947-4-1 1500 V VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc at 40...400 Hz (at Drop-out: 0.35...0.55 Uc at 40...400 Hz (at <131 °F (55 °C))","Power Pole Contact Composition":"3 x 3 NO","[Ie] rated operational current":"265 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 for power circuit","[Ue] rated operational voltage":"Power circuit <= 1000 V AC 16 Hz 2/3...200 Hz","Hold-in power consumption in VA":"10 VA 40...400 Hz cos phi 0.9 (at 68 °F (20 °C))","Ambient Air Temperature for Storage":"-76...176 °F (-60...80 °C)","Ambient air temperature for operation":"23...131 °F (-5...55 °C) -40...158 °F (-40...70 °C) at Uc","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 104 °F (40 °C) - 10 s 1230 A 104 °F (40 °C) - 30 s 950 A 104 °F (40 °C) - 1 min 620 A 104 °F (40 °C) - 3 min 480 A 104 °F (40 °C) - 10 min","[Ith] conventional free air thermal current":"350 A 104 °F (40 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/89eb09f8b0225addd13b69d181dc3e2c.pdf","sourceUrl":"https://www.se.com/ie/en/product/LC3F265M7A64/tesys-f-star-delta-starter-3-x-3p-3-no-265-a-220-230-v-ac-coil/"},"ai":{"faq":[{"question":"What are the motor power ratings for this star delta starter?","answer":"Motor power ratings are 110 kW at 220/230 V AC, 220 kW at 380/400 V AC, 220 kW at 415 V AC, and 250 kW at 440 V AC, all at 50/60 Hz."},{"question":"What auxiliary contacts are included?","answer":"The unit includes 1 NC and 1 NO on the KM1 star contactor, 2 NC and 1 NO on the KM2 line contactor, and 1 NC and 2 NO on the KM3 delta contactor."},{"question":"What is the control circuit voltage?","answer":"The control circuit voltage is 220/230 V AC at 50/60 Hz, with an operational range of 0.85 to 1.1 Uc for pick-up and a drop-out range of 0.35 to 0.55 Uc."},{"question":"What standards does this part comply with?","answer":"It complies with EN 60947-4-1, IEC 60947-4-1, EN 60947-1, IEC 60947-1, and JIS C8201-4-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC3F265M7A64","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC3F265M7A64 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}