{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC3F265Q7A64","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC3F265Q7A64","canonicalUrl":"https://aoctrl.com/schneider/LC3F265Q7A64","factsUrl":"https://aoctrl.com/api/mcp/products/LC3F265Q7A64","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys F LC3F265Q7A64, pre-wired star delta starter, 3 x 3P, 265 A AC-3, 380/400 V AC 50/60 Hz control, mechanical interlock.","salesMarkdown":"The Schneider Electric LC3F265Q7A64 is a pre-wired TeSys F star delta starter, purpose-built for motor control in the AC-3 utilisation category. It's a three-pole assembly with a mechanical interlock, designed to reduce inrush current during motor startup by first connecting the windings in star configuration, then switching to delta for run. Rated operational current is 265 A at <= 440 V AC, AC-3 duty, which translates to motor power ratings of 110 kW at 220/230 V, 220 kW at 380/400 V and 415 V, and 250 kW at 440 V — all at 50/60 Hz. Control circuit voltage is 380/400 V AC 50/60 Hz, with an operational range of 0.85 to 1.1 Uc and a drop-out window of 0.35 to 0.55 Uc. Inrush power is 650 VA at 40...400 Hz, cos phi 0.9, at 20 °C. The associated fuse rating is 400 A gG or 315 A aM at <= 440 V, so the upstream protection should be coordinated to those values. The rated breaking capacity is 2120 A, and the rated making capacity is 2650 A, both conforming to IEC 60947-4-1. These numbers tell you the contactor set is built for frequent, heavy-duty cycling — not a once-a-day pump start. Auxiliary contact composition is pre-configured: 1 NC and 1 NO for the KM1 star contactor, 2 NC and 1 NO for the KM2 line contactor, and 1 NC and 2 NO for the KM3 delta contactor. That's a complete interlocking and signalling set built in — no separate aux blocks needed for standard star-delta logic. Mounting is plate-style — not DIN rail — so plan for a backplate or sub-panel in the enclosure. Dimensions are 625 mm wide, 110 mm high, and 266 mm deep. Power circuit connections are bolted, using M10 bolts, bar (32 x 4 mm busbar cross-section), or lugs/ring terminals up to 240 mm². Control circuit connections are screw clamp terminals accepting 1 to 4 mm² flexible or solid cable. Front face achieves IP20 with shrouds, conforming to IEC 60529 and VDE 0106 — suitable for enclosed panel installation where no one's reaching into live parts. Protective treatment is TH (tropicalised) for humid environments. Standards compliance includes IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. These certifications cover the regulatory acceptance for most industrial control panels globally.","metaTitle":"Schneider Electric LC3F265Q7A64 TeSys F Star Delta Starter,","metaDescription":"Schneider Electric LC3F265Q7A64 TeSys F star delta starter. 265 A rated operational current at <=440 V AC-3, 220 kW at 400 V. Pre-wired, mechanical interlock. Current production. S","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"266 mm","Range":"TeSys","Width":"625 mm","Height":"110 mm","Standards":"IEC 60947-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-4-1 EN 60947-1","Product name":"TeSys F","Starting time":"30 s","Motor power kW":"110 kW at 220/230 V AC 50/60 Hz 220 kW at 380/400 V AC 50/60 Hz 220 kW at 415 V AC 50/60 Hz 250 kW at 440 V AC 50/60 Hz","Operating time":"40...65 ms closing 100...170 ms opening","lifecycle_stage":"current","Heat dissipation":"8 W","Mounting support":"Plate","Device short name":"LC3F","Interlocking type":"Mechanical","Poles description":"3 x 3P","Tightening torque":"Control circuit: 1.2 N.m Power circuit: 35 N.m","Inrush power in VA":"650 VA 40...400 Hz cos phi 0.9 (at 20 °C)","Operating altitude":"3000 m without derating","Device presentation":"Pre-wired","Control circuit type":"AC at 50/60 Hz","Protective treatment":"TH","Utilisation category":"AC-3","Contactor application":"Motor control","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open: 2 Gn, 5...300 Hz Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms","Associated fuse rating":"400 A gG at 315 A aM at <= 440 V","Maximum operating rate":"2400 cyc/h 55 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid without cable end Power circuit: bar 2 - busbar cross section: 32 x 4 mm Power circuit: bolted connection Power circuit: lugs-ring terminals 1 240 mm² Power circuit: connector 1 240 mm²","IP degree of protection":"IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106","Rated breaking capacity":"2120 A conforming to IEC 60947-4-1","Connections Bolt Diameter":"M10","Product or component type":"Star delta starter","Irms rated making capacity":"2650 A conforming to IEC 60947-4-1","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Auxiliary contact composition":"1 NC for KM1 star contactor 1 NO for KM1 star contactor 2 NC for KM2 line contactor 1 NO for KM2 line contactor 1 NC for KM3 delta contactor 2 NO for KM3 delta contactor","[Ui] rated insulation voltage":"1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C","Control circuit voltage limits":"Operational: 0.85...1.1 Uc at 40...400 Hz (at Drop-out: 0.35...0.55 Uc at 40...400 Hz (at <55 °C)","Power Pole Contact Composition":"3 x 3 NO","[Ie] rated operational current":"265 A (at <55 °C) at <= 440 V AC AC-3 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz","Hold-in power consumption in VA":"10 VA 40...400 Hz cos phi 0.9 (at 20 °C)","Ambient air temperature for storage":"-60...80 °C","Ambient air temperature for operation":"-5...55 °C -40...70 °C at Uc","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"2200 A 40 °C - 10 s 1230 A 40 °C - 30 s 950 A 40 °C - 1 min 620 A 40 °C - 3 min 480 A 40 °C - 10 min","[Ith] conventional free air thermal current":"350 A 40 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/81da3ac8261826e2e0cec5ff337cc62c.pdf","sourceUrl":"https://www.se.com/vn/en/product/LC3F265Q7A64/tesys-f-star-delta-starter-3-x-3p-3-no-265-a-380-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LC3F265Q7A64/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this star delta starter?","answer":"Rated operational current is 265 A at <= 440 V AC, AC-3 duty. Motor power ratings are 110 kW at 220/230 V, 220 kW at 380/400 V and 415 V, and 250 kW at 440 V. Control circuit voltage is 380/400 V AC 50/60 Hz."},{"question":"What compliance documentation does this part carry?","answer":"It conforms to IEC 60947-1, IEC 60947-4-1, EN 60947-1, EN 60947-4-1, and JIS C8201-4-1. Rated insulation voltage is 1000 V per IEC 60947-4-1 and 1500 V per VDE 0110 group C. Front face protection is IP20 with shrouds."},{"question":"What is the mounting and connection method?","answer":"Mounting is plate-style (not DIN rail). Power connections use M10 bolts, bar (32 x 4 mm), or lugs up to 240 mm². Control connections are screw clamp terminals for 1 to 4 mm² cable. Dimensions are 625 x 110 x 266 mm (W x H x D)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC3F265Q7A64","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC3F265Q7A64 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}