{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LC7K09017FE7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LC7K09017FE7","canonicalUrl":"https://aoctrl.com/schneider/LC7K09017FE7","factsUrl":"https://aoctrl.com/api/mcp/products/LC7K09017FE7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K, 3-pole contactor, AC-3 ≤440 V 9 A, 1 NC auxiliary, 115 V AC coil, 4 kW at 480 V AC.","salesMarkdown":"## Part Profile The LC7K09017FE7 is a Schneider Electric TeSys K 3-pole contactor with a 115 V AC coil and one normally closed auxiliary contact. It's rated for AC-3 duty at 9 A up to 440 V, and carries motor power ratings of 4 kW at 480 V, 500–600 V, 660–690 V, 380–415 V, and 440 V AC, plus 2.2 kW at 220–230 V AC, all at 50/60 Hz. The AC-1 and AC-4 utilisation categories are also covered, meaning it handles resistive loads and inching/jogging duty as well. For resistive (AC-1) or plugging/inching (AC-4) duty, the rated operational current is 20 A, so the same contactor handles higher resistive loads but the AC-3 figure governs typical induction motor applications. The 4 kW across multiple voltage bands (480 V through 690 V) confirms it's sized for standard three-phase motors in that power class globally, not just one regional voltage. Heat dissipation is 3 W — low enough that multiple units can be ganged on a DIN rail without forced cooling in a standard IP20 panel. The 3-pole configuration (3 NO main poles) with a single NC auxiliary covers basic control interlocking; if you need more aux contacts, plan an add-on block. This is a panel-mount contactor for motor control in industrial machinery, conveyors, pumps, and compressors. The 45 mm width and 58 mm height fit standard TeSys K rail or screw-mounting footprints — common in small-to-medium control panels where space is tight. The 115 V AC coil is a North American standard control voltage; verify your control transformer or PLC output matches.","metaTitle":"TeSys K LC7K09017FE7 Contactor, 3P, 9 A AC-3, 115 VAC Coil","metaDescription":"Active TeSys K 3-pole contactor, AC-3 rated 9 A at ≤440 V, 115 VAC coil, 1 NC auxiliary. UL 94 V1 flame retardance. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LC7K09017FE7","Height":"58 mm","description":"TeSys K contactor, 3P, AC-3 <= 440 V 9 A, 1 NC aux., 115 V AC coil","Product name":"TeSys K","Motor power kW":"4 kW at 480 V AC 50/60 Hz 4 kW at 500...600 V AC 50/60 Hz 4 kW at 660...690 V AC 50/60 Hz 2.2 kW at 220...230 V AC 50/60 Hz 4 kW at 380...415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"3 W","Range of product":"TeSys K","Device short name":"LC7K","Poles description":"3P","Compatibility code":"LC7K","Device application":"Control","Utilisation category":"AC-1 AC-4 AC-3","Pole contact composition":"3 NO","Product or component type":"Contactor","[Ie] rated operational current":"20 A (at 9 A at 16 A (at 10 MOhm for signalling circuit","[Icw] rated short-time withstand current":"90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit 80 A - 1 s for signalling circuit 90 A - 500 ms for signalling circuit 110 A - 100 ms for signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/57584ddef59d1c230ab9563e6549de5b.pdf","sourceUrl":"https://www.se.com/in/en/product/LC7K09017FE7/tesys-k-contactor-3p-ac3-440-v-9-a-1-nc-aux-115-v-ac-coil/"},"ai":{"faq":[{"question":"What are the key motor power ratings for this contactor?","answer":"It is rated for 4 kW at 480 V, 500–600 V, 660–690 V, 380–415 V, and 440 V AC, and 2.2 kW at 220–230 V AC, all at 50/60 Hz. The AC-3 operational current is 9 A at ≤440 V."},{"question":"What is the physical size of the LC7K09017FE7?","answer":"Width 45 mm, height 58 mm, depth 57 mm. It fits the standard TeSys K panel footprint."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries UL 94 V1 flame retardance and NF F 16-101/102 railway fire compliance. The TeSys K series is typically UL, CSA, CE, and CCC certified; specific documentation should be confirmed at order."},{"question":"What is the closest alternative to this contactor in the TeSys K family?","answer":"Within the TeSys K range, the key variant is coil voltage — the LC7K09017FE7 uses a 115 V AC coil. A sibling with a different coil voltage (e.g., 24 V AC/DC or 230 V AC) would be the same physical contactor with a different order code. No pin-compatible drop-in from another series exists without footprint changes."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LC7K09017FE7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LC7K09017FE7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}