{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LE4D25G7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LE4D25G7","canonicalUrl":"https://aoctrl.com/schneider/LE4D25G7","factsUrl":"https://aoctrl.com/api/mcp/products/LE4D25G7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LE series, enclosed DOL starter, LE4D25G7, 25 A, 120 V AC coil, IP65.","salesMarkdown":"Rated at 25 A conventional free-air thermal current (Ith) and AC-3 utilisation category, it handles motor loads up to 11 kW at 380/400/415/440 V AC and 15 kW at 500 V AC — covering standard three-phase induction motors in that power band. ## Deployment context IP65 and IK07 protection let this starter live on the machine frame in washdown areas, outdoors under a roof, or on a plant wall — no separate enclosure needed. Cable entries on top and bottom accept ISO20 through ISO40 glands, so it's ready for standard armoured or flexible conduit runs. The polycarbonate body is tough enough for most industrial environments but keep it out of direct solvent spray; it's rated for -5 to 40 °C ambient. ## Lifecycle reality No direct official successor order code is published in the available records. The 25 A Ith rating is the thermal current in open air — the continuous current the starter's power path can carry without exceeding temperature rise limits. Associated fuse rating of 25 A aM (10 x 38 mm) gives short-circuit protection coordinated with the starter — the aM characteristic handles motor inrush without nuisance blowing while clearing faults fast enough to protect the contactor. Built to IEC 60947-4-1, the standard for contactors and motor-starters. That covers the whole assembly — contactor, overload (ordered separately), and enclosure — as a coordinated unit.","metaTitle":"Schneider Electric LE4D25G7 TeSys LE Enclosed DOL Starter, 2","metaDescription":"Obsolete Schneider Electric LE4D25G7 enclosed DOL starter, 25 A, 120 V AC coil. IP65, AC-3 rated for 11 kW at 400 V. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Overload Relays"],"specifications":{"Depth":"175.5 mm","Range":"TeSys","Width":"186 mm","Height":"330 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1","Control type":"Push-button start green I Push-button stop/reset red O","Product name":"TeSys LE","Motor power kW":"11 kW at 380/400 V AC 50/60 Hz 11 kW at 415 V AC 50/60 Hz 11 kW at 440 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 5.5 kW at 220/230 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LE4D","Cable entry number":"2 ISO20 top 2 ISO25 top 2 ISO32 top 2 ISO40 top 2 ISO20 bottom 2 ISO25 bottom 2 ISO32 bottom 2 ISO40 bottom","Device application":"Standard","Device composition":"Thermal overload relay ordered separately Contactor Fuse disconnector","Utilisation category":"AC-3","Associated fuse rating":"25 A 10 x 38 mm aM","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP65 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"120 V AC 50/60 Hz","Ambient air temperature for operation":"-5...40 °C","[Ith] Conventional free air thermal current":"25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/uk/en/product/LE4D25G7/tesys-le-enclosed-dol-starter-25-a-120-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LE4D25G7/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LE4D25G7?","answer":"No official successor order code is published in the available records. The part must be sourced through the surplus or broker channel."},{"question":"What motor power does the LE4D25G7 cover?","answer":"It handles 11 kW at 380/400/415/440 V AC and 15 kW at 500 V AC, all at 50/60 Hz, in AC-3 duty. At 220/230 V AC it covers 5.5 kW."},{"question":"What enclosure rating does it carry?","answer":"IP65 per IEC 60529 and IK07 per IEC 60529. Suitable for washdown and outdoor sheltered locations."},{"question":"What control voltage does the coil need?","answer":"120 V AC at 50/60 Hz. The built-in push buttons are wired to this control circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LE4D25G7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LE4D25G7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}