{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LE4K095P7","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LE4K095P7","canonicalUrl":"https://aoctrl.com/schneider/LE4K095P7","factsUrl":"https://aoctrl.com/api/mcp/products/LE4K095P7","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LE, enclosed DOL starter, 9 A, 230 V AC coil, 4 kW at 400 V AC-3, IP65, IEC 60947-4-1.","salesMarkdown":"It is designed to start and stop three-phase squirrel-cage motors within its rating envelope, built into a polycarbonate enclosure rated IP65 and IK09 for resistance to dust ingress, low-pressure water jets, and mechanical impact of 2 J. ## Motor Duty and Application Context Rated for AC-3 utilisation category per IEC 60947-4-1, this starter switches 4 kW at 380/400 V AC 50/60 Hz and 4 kW at 415 V and 440 V, with a reduced 2.2 kW rating at 220/230 V. The 9 A thermal current and 12 A aM fuse recommendation set the upstream protection boundary — the starter itself contains no overload relay; a separate thermal overload must be ordered and wired in series. The IP65 enclosure makes it suitable for installation directly on machine frames or in washdown zones where a panel-mounted contactor would require a separate enclosure. The enclosure measures 175 mm wide, 165 mm high, and 146 mm deep, with multiple cable entry options: four ISO20 knockouts (top and bottom) plus two Pg 13 and two Pg 16 entries on the top face. The polycarbonate housing is self-extinguishing and carries the IK09 impact rating, so it withstands incidental tool strikes during maintenance. The push-button control — green start and red stop/reset — is integrated into the enclosure cover, eliminating the need for a separate control station in simple local-start applications.","metaTitle":"Schneider Electric LE4K095P7 TeSys LE Enclosed DOL Starter,","metaDescription":"Schneider Electric LE4K095P7 TeSys LE enclosed DOL starter, 9 A, 230 V AC coil, 4 kW at 400 V AC-3, IP65. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Overload Relays"],"specifications":{"Depth":"146 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1","Control type":"Push-button start green I Push-button stop/reset red O","Product name":"TeSys LE","Motor power kW":"4 kW at 380/400 V AC 50/60 Hz 4 kW at 415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 2.2 kW at 220/230 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LE4K","Cable entry number":"4 ISO20 top 4 2 Pg 13 + 2 Pg 16 top 4 ISO20 bottom 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Standard","Device composition":"Thermal overload relay ordered separately Contactor Fuse disconnector","Utilisation category":"AC-3","Associated fuse rating":"12 A 10 x 38 mm aM","IK degree of protection":"IK09 conforming to IEC 60529","IP degree of protection":"IP65 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"230 V AC 50/60 Hz","Ambient air temperature for operation":"-5...40 °C","[Ith] Conventional free air thermal current":"9 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f2814d35619c28e241e0b9b121476184.pdf","sourceUrl":"https://www.se.com/nz/en/product/LE4K095P7/tesys-le-enclosed-dol-starter-9-a-230-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LE4K095P7/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the LE4K095P7?","answer":"No official successor order code is listed in the available records. A replacement would need to match the 9 A AC-3 rating, 230 V AC coil, IP65 enclosure, and 4 kW motor capacity at 400 V — a review of current TeSys LE or TeSys island catalogues is required."},{"question":"What are the key ratings for the LE4K095P7?","answer":"The starter is rated 9 A conventional free-air thermal current (Ith), AC-3 utilisation category, 4 kW at 400 V AC, with a 230 V AC control coil. It requires a separate thermal overload relay and a 12 A aM fuse for upstream protection."},{"question":"What environmental protection does the LE4K095P7 offer?","answer":"The polycarbonate enclosure is rated IP65 (dust-tight and protected against water jets) and IK09 (impact energy of 2 J), making it usable in washdown or machine-side locations without a secondary enclosure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LE4K095P7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LE4K095P7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}