{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG1K065N707","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG1K065N707","canonicalUrl":"https://aoctrl.com/schneider/LG1K065N707","factsUrl":"https://aoctrl.com/api/mcp/products/LG1K065N707","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG series, LG1K065N707, enclosed DOL starter, 1.6...2.5 A thermal protection, 400/415 V AC coil, IP55, polycarbonate enclosure.","salesMarkdown":"The Schneider Electric TeSys LG1K065N707 is an enclosed direct-on-line (DOL) starter combining a contactor, switch disconnector, and circuit-breaker in a single IP55 polycarbonate enclosure — a self-contained motor start-and-protect package for standard-environment industrial lines. Rated for AC-3 duty, it handles a 0.37 kW motor at 220/230 V AC, 0.75 kW at 400/415 V AC, and 1.1 kW at 440 V AC, all at 50/60 Hz. The thermal protection adjustment range of 1.6...2.5 A lets it match small three-phase induction motors — think pumps, fans, or small conveyors — and the IP55 enclosure means it can sit on the machine frame or near the line, not just in a sealed panel. This part is obsolete per Schneider's lifecycle status, so it is no longer in active factory production. If you are qualifying a form-fit-function replacement, the deciding specs to match are the 1.6...2.5 A thermal adjustment range, the 400/415 V AC coil voltage, the AC-3 utilization category, and the IP55 polycarbonate enclosure — any substitute must hold those same ratings to drop in without a panel rework. The enclosure carries four cable entries — two Pg 13 and two Pg 16 at both top and bottom — which gives enough room for the incoming mains and the motor leads plus a control loop. At 165 mm deep, 175 mm wide, and 165 mm tall, the polycarbonate box fits a standard machine-mount footprint. The IK07 impact rating means it withstands the occasional tool bump on the line floor, and compliance with IEC 60204-1 (machinery safety) and IEC 60947-4-1 (contactors and motor-starters) covers the electrical safety documentation for a CE-declared machine.","metaTitle":"TeSys LG1K065N707 Enclosed DOL Starter, 1.6-2.5 A, Obsolete","metaDescription":"TeSys LG1K065N707 enclosed DOL starter, 1.6-2.5 A thermal protection, 400/415 V AC coil, IP55. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Rotary handle emergency stop red","Product name":"TeSys LG","Motor power kW":"0.37 kW at 220/230 V AC 50/60 Hz 0.75 kW at 400/415 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG1K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Switch disconnector Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"400/415 V AC 50/60 Hz","Thermal protection adjustment range":"1.6...2.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c36f72b3a23e654ef0eedae3c2fce4fa.pdf","sourceUrl":"https://www.se.com/ie/en/product/LG1K065N707/tesys-lg-enclosed-dol-starter-1-6-2-5-a-400-415-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG1K065N707/alternatives.json"},"ai":{"faq":[{"question":"Is LG1K065N707 obsolete?","answer":"Yes, LG1K065N707 is obsolete per Schneider Electric's lifecycle status. It is no longer in active factory production and must be sourced through surplus or independent distribution channels."},{"question":"What is the replacement for LG1K065N707?","answer":"No official successor order code is listed in the lifecycle record for LG1K065N707. A form-fit-function replacement must match the 1.6...2.5 A thermal adjustment range, the 400/415 V AC coil, AC-3 duty rating, and IP55 polycarbonate enclosure."},{"question":"What is the difference between TeSys LG and TeSys GV?","answer":"TeSys LG is an enclosed DOL starter — a self-contained unit with contactor, switch disconnector, and circuit-breaker in an IP55 box, ready for direct machine mounting. TeSys GV refers to Schneider's manual motor starters and disconnect switches, typically panel-mounted or DIN-rail components that are part of a larger starter assembly rather than a complete enclosed starter."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG1K065N707","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG1K065N707 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}