{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG1K065Q704","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG1K065Q704","canonicalUrl":"https://aoctrl.com/schneider/LG1K065Q704","factsUrl":"https://aoctrl.com/api/mcp/products/LG1K065Q704","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG enclosed DOL starter, LG1K065Q704, 0.4-0.63 A thermal protection, 380/400 V AC coil, IP55, obsolete.","salesMarkdown":"The Schneider Electric TeSys LG1K065Q704 is an enclosed DOL (direct-on-line) starter combining a contactor, switch-disconnector, and circuit-breaker in one IP55 polycarbonate enclosure. It is rated for AC-3 motor duty at 0.18 kW on 400/415 V AC supplies, with a thermal protection adjustment range of 0.4 to 0.63 A and a 380/400 V AC control coil. The IP55 rating means the enclosure is dust-protected and withstands water jets from any direction — suitable for washdown areas in food processing or light industrial environments where hose-down cleaning is routine. The IK07 impact rating confirms it resists 2 J impacts, enough for accidental tool drops in a panel bay. ## Integration notes for panel builders Cable entries include four Pg 13 and two Pg 16 knockouts on both top and bottom faces, giving flexibility for top-entry or bottom-entry wiring in a panel gland plate. The polycarbonate enclosure is lightweight and corrosion-resistant, but the IP55 seal means gland nuts must be properly torqued to maintain the rating. The front panel carries a white push-button start, black push-button stop, and a red rotary emergency stop handle — all pre-wired to the internal contactor and disconnect. The thermal overload adjustment range of 0.4 to 0.63 A is set via a dial inside the enclosure. For a 0.18 kW motor at 400 V (full-load current typically around 0.5 A), set the dial to the motor nameplate FLA. The unit complies with IEC 60204-1 for electrical equipment of machines, so it meets the safety standard for machine control panels.","metaTitle":"TeSys LG1K065Q704 Enclosed DOL Starter, 0.4-0.63 A, Obsolete","metaDescription":"Schneider TeSys LG1K065Q704 enclosed DOL starter, 0.4-0.63 A thermal range, 380/400 V AC coil, IP55. Obsolete — sourced to order against RFQ via independent channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1 IEC 60204-1","Control type":"Push-button start white I Push-button stop black O Rotary handle emergency stop red","Product name":"TeSys LG","Motor power kW":"0.18 kW at 400/415 V AC 50/60 Hz 0.18 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG1K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Switch disconnector Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Thermal protection adjustment range":"0.4...0.63 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4507e516f345d1bdc6a1ccde3c36492b.pdf","sourceUrl":"https://www.se.com/be/en/product/LG1K065Q704/tesys-lg-enclosed-dol-starter-0-40-0-63-a-380-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG1K065Q704/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy LG1K065Q704 and how is it quoted?","answer":"This obsolete part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or price figures can be stated here. Submit an RFQ for a firm quote on your required quantity."},{"question":"What is the thermal protection range of LG1K065Q704?","answer":"The thermal overload relay inside this enclosed starter adjusts from 0.4 to 0.63 A. This covers the full-load current of a 0.18 kW motor at 400/415 V AC (AC-3 duty)."},{"question":"What compliance standards does LG1K065Q704 meet?","answer":"It complies with IEC 60947-4-1 (low-voltage switchgear for motor starting) and IEC 60204-1 (safety of machinery — electrical equipment). The enclosure carries IP55 and IK07 ratings per IEC 60529."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG1K065Q704","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG1K065Q704 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}