{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG1K065Q710A37","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG1K065Q710A37","canonicalUrl":"https://aoctrl.com/schneider/LG1K065Q710A37","factsUrl":"https://aoctrl.com/api/mcp/products/LG1K065Q710A37","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG enclosed DOL starter, LG1K065Q710A37, 4…6.3 A thermal protection, 380/400 V AC coil, IP55, mushroom-head emergency stop.","salesMarkdown":"The Schneider Electric TeSys LG1K065Q710A37 is an enclosed direct-on-line (DOL) starter that integrates a contactor, switch disconnector, and circuit-breaker in a single polycarbonate enclosure rated IP55 and IK07. It is designed for standard-environment motor starting and safety isolation, with a thermal protection adjustment range of 4…6.3 A and an AC-3 utilization category for three-phase induction motors up to 3 kW at 440 V AC. Cable entries are provided: 4 Pg 13 + 2 Pg 16 at both top and bottom. Because this is an obsolete part, buyers should verify fit against the original application and consider whether an official replacement or a functionally equivalent enclosed starter from the current TeSys range can be specified. The manufacturer's lifecycle documentation may list a successor order code; if none is available, a parametric cross-reference based on motor power, thermal range, and enclosure rating is the practical path. The 4…6.3 A thermal protection adjustment range sets the motor full-load current window this starter can protect. For a 3 kW motor at 440 V AC (AC-3 duty), the thermal overload is set within that band. The IK07 impact rating means the enclosure withstands a 2 J impact — adequate for general panel or machine-side mounting. ## Deployment context This enclosed DOL starter is a self-contained unit — no separate contactor, overload relay, or enclosure to assemble. It mounts directly to a machine frame or wall via the polycarbonate enclosure's fixing points. The cable entries (Pg 13 and Pg 16) accept standard industrial cable glands for motor and supply wiring. The integrated push-button controls and emergency stop reduce external panel wiring. The rotary-handle emergency stop provides a lockable, positive-break isolation point that satisfies IEC 60204-1 and IEC 60947-4-1 requirements for safety disconnection.","metaTitle":"TeSys LG1K065Q710A37 Enclosed DOL Starter, 4…6.3 A, Obsolete","metaDescription":"Schneider TeSys LG1K065Q710A37 enclosed DOL starter, 4…6.3 A thermal range, 380/400 V AC coil, IP55. Obsolete — sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Rotary handle emergency stop red Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"3 kW at 440 V AC 50/60 Hz 1.1 kW at 220/230 V AC 50/60 Hz 2.2 kW at 400/415 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG1K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Switch disconnector Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Thermal protection adjustment range":"4...6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e0af3b4e61d22561e8e382c55459a4e2.pdf","sourceUrl":"https://www.se.com/sg/en/product/LG1K065Q710A37/tesys-lg-enclosed-dol-starter-4-6-3-a-380-400-v-ac-coil-mushroom-head/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG1K065Q710A37/alternatives.json"},"ai":{"faq":[{"question":"What is the replacement for LG1K065Q710A37?","answer":"The manufacturer's lifecycle record does not list a direct successor order code for the LG1K065Q710A37. To find a functional replacement, compare the required motor power (up to 3 kW at 440 V AC), thermal protection range (4…6.3 A), control voltage (380/400 V AC), and enclosure rating (IP55) against current TeSys enclosed starter offerings."},{"question":"What are the specifications of LG1K065Q710A37?","answer":"The LG1K065Q710A37 is an enclosed DOL starter with a thermal protection adjustment range of 4…6.3 A, a 380/400 V AC 50/60 Hz control coil, and an AC-3 utilization category. It is rated for motors up to 3 kW at 440 V AC. The enclosure is polycarbonate, IP55, IK07, and measures 165 mm deep by 175 mm wide by 165 mm high."},{"question":"Where to buy LG1K065Q710A37?","answer":"The LG1K065Q710A37 is sourced to order against an RFQ through independent distribution channels. Submit a request for quote to confirm current availability and pricing — this part is not held in standard stocking quantities due to its obsolete status."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG1K065Q710A37","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG1K065Q710A37 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}