{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG1K065V702","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG1K065V702","canonicalUrl":"https://aoctrl.com/schneider/LG1K065V702","factsUrl":"https://aoctrl.com/api/mcp/products/LG1K065V702","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG, enclosed DOL starter, 0.16...0.25 A thermal protection, 400 V AC 50/60 Hz coil, IP55, polycarbonate enclosure.","salesMarkdown":"The Schneider Electric TeSys LG1K065V702 is an enclosed direct-on-line (DOL) starter, combining a contactor, switch disconnector, and circuit-breaker in a single IP55 polycarbonate enclosure rated IK07. It is designed for safety applications per IEC 60947-4-1 and IEC 60204-1, providing coordinated motor starting, overload protection, and isolation in a compact package. The thermal protection adjustment range is 0.16...0.25 A, sized for the smallest fractional-horsepower motors — think 0.06 kW at 400/415 V AC or 440 V AC, 50/60 Hz. The control circuit coil is 400 V AC, so the starter is line-voltage controlled without a separate control transformer. The front panel carries a white push-button for start, a black push-button for stop, and a red rotary-handle emergency stop, giving local operator control and an E-stop that satisfies safety-circuit isolation requirements. ## Lifecycle status and sourcing reality No manufacturer lead time applies — this is a last-time-buy or broker-market part. The 0.16...0.25 A thermal range directly sets the motor full-load current it protects; if your motor nameplate falls outside that window, the starter cannot be field-adjusted to cover it. IP55 with IK07 impact resistance means the enclosure withstands hose-directed water and dust ingress, plus a 0.5 J impact — suitable for washdown areas or floor-mounted locations near the machine, provided ambient conditions stay within standard environmental limits. The polycarbonate material is UV-stable for indoor industrial use but should not be relied on for direct-sunlight outdoor exposure over years. Cable entries are 4 knockouts: 2 x Pg 13 and 2 x Pg 16 at both top and bottom. That gives flexibility for top-entry or bottom-entry conduit runs, but the Pg thread is metric — verify your cable gland compatibility if you are working in an NPT-standard plant.","metaTitle":"Schneider TeSys LG1K065V702 Enclosed DOL Starter","metaDescription":"Schneider TeSys LG1K065V702 enclosed DOL starter, 0.16-0.25 A thermal range, 400 V AC coil, IP55. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1 IEC 60204-1","Control type":"Push-button start white I Push-button stop black O Rotary handle emergency stop red","Product name":"TeSys LG","Motor power kW":"0.06 kW at 400/415 V AC 50/60 Hz 0.06 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG1K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Switch disconnector Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"400 V AC 50/60 Hz","Thermal protection adjustment range":"0.16...0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b4e36abea311db81b5ab3ec611af7251.pdf","sourceUrl":"https://www.se.com/sg/en/product/LG1K065V702/tesys-lg-enclosed-dol-starter-0-16-0-25-a-400-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG1K065V702/alternatives.json"},"ai":{"faq":[{"question":"What is the replacement for LG1K065V702?","answer":"No official successor order code is listed in the manufacturer's lifecycle record. For a direct replacement, you would need to review the current TeSys LG or TeSys GV2/GV3 enclosed starter range for a part with the same 0.16...0.25 A thermal range, 400 V AC coil, and IP55 enclosure. We can assist with cross-referencing against an RFQ."},{"question":"What are the specifications of LG1K065V702?","answer":"It is an enclosed DOL starter with a 0.16...0.25 A thermal protection range, 400 V AC 50/60 Hz coil, AC-3 utilisation category, IP55 polycarbonate enclosure (IK07), and dimensions 175 x 165 x 165 mm (W x H x D). It integrates a contactor, switch disconnector, and circuit-breaker for safety applications per IEC 60947-4-1."},{"question":"Does LG1K065V702 include a circuit breaker or overload protection?","answer":"Yes, the device composition includes a circuit-breaker and a contactor with thermal overload protection adjustable from 0.16 to 0.25 A. The switch disconnector provides visible isolation for safe maintenance access."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG1K065V702","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG1K065V702 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}