{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG1K095Q714A37","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG1K095Q714A37","canonicalUrl":"https://aoctrl.com/schneider/LG1K095Q714A37","factsUrl":"https://aoctrl.com/api/mcp/products/LG1K095Q714A37","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys LG enclosed DOL starter, LG1K095Q714A37, 6-10 A thermal protection, 380/400 V AC coil, 4 kW at 400 V AC-3, IP55 polycarbonate enclosure.","salesMarkdown":"## Enclosed DOL starter for 4 kW motor duty The Schneider LG1K095Q714A37 is a TeSys LG enclosed direct-on-line starter rated for 4 kW at 400/415 V AC 50/60 Hz in AC-3 utilisation category, meaning it handles the starting and stopping of standard three-phase squirrel-cage induction motors up to that power without external contactor or overload assembly. The 380/400 V AC 50/60 Hz control circuit voltage means the coil energises directly from a standard 400 V three-phase control supply; no step-down transformer or separate control voltage is needed for the starter's own operation. ## Built-in components and enclosure This enclosed starter integrates a contactor, a switch disconnector, and a circuit-breaker in one IP55 polycarbonate enclosure rated IK07 for impact resistance — suitable for wall-mounting in industrial environments where washdown or dust ingress is a concern. The control interface includes a white push-button for start, a black push-button for stop, and a red rotary handle for emergency stop plus a red mushroom-head emergency stop push-button, giving operators both a local run/stop station and a lockable emergency stop on the enclosure face. Four cable entries are provided — 2 x Pg 13 and 2 x Pg 16 at both top and bottom — allowing incoming supply and outgoing motor cables to be glanded without drilling additional holes. ## Standards compliance and lifecycle The LG1K095Q714A37 is designed to IEC 60204-1 (safety of machinery — electrical equipment) and IEC 60947-4-1 (contactors and motor-starters), so it meets the machinery directive requirements for a motor branch circuit in a CE-marked panel. The product lifecycle status is active, meaning Schneider continues to manufacture this order code without a published end-of-life notice — it remains a current catalog item for new installations and spares restocking.","metaTitle":"Schneider LG1K095Q714A37 TeSys LG Enclosed DOL Starter","metaDescription":"Schneider TeSys LG LG1K095Q714A37 enclosed DOL starter, 6-10 A thermal range, 4 kW at 400 V AC-3, 380/400 V AC coil, IP55. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Starters"],"specifications":{"Depth":"165 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Rotary handle emergency stop red Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 1.5 kW at 220/230 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG1K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Switch disconnector Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Thermal protection adjustment range":"6...10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b6b3db7be4f6f132ef12647b2dffb0ab.pdf","sourceUrl":"https://www.se.com/ie/en/product/LG1K095Q714A37/tesys-lg-enclosed-dol-starter-6-10-a-380-400-v-ac-coil-mushroom-head/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG1K095Q714A37/alternatives.json"},"ai":{"faq":[{"question":"Is LG1K095Q714A37 suitable for a 4 kW 400 V three-phase motor?","answer":"Yes, it is rated for 4 kW at 400/415 V AC 50/60 Hz in AC-3 utilisation category, which covers starting and stopping of a standard three-phase induction motor at that power."},{"question":"Does LG1K095Q714A37 include an overload relay?","answer":"Yes, the enclosed starter includes a circuit-breaker with thermal protection adjustable from 6 to 10 A, which functions as the overload relay for the motor branch."},{"question":"What is the difference between LG1K095Q714A37 and LG1K095Q714A36?","answer":"The LG1K095Q714A37 has a 380/400 V AC coil, while the LG1K095Q714A36 uses a different control voltage — verify the coil voltage on your BOM to select the correct variant."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG1K095Q714A37","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG1K095Q714A37 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}