{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06B705","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06B705","canonicalUrl":"https://aoctrl.com/schneider/LG7K06B705","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06B705","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG series, LG7K06B705, enclosed DOL starter, 0.63…1 A thermal protection, 24 V AC 50/60 Hz coil, IP55, polycarbonate enclosure.","salesMarkdown":"The Schneider Electric LG7K06B705 is an enclosed direct-on-line (DOL) starter from the TeSys LG family, combining a contactor and a circuit-breaker in a single IP55 polycarbonate enclosure. It is designed for safety applications and provides motor starting and overload protection in a ready-to-mount package. Rated for AC-3 utilization category, it delivers 0.12 kW at 220/230 V AC, 0.25 kW at 400/415 V AC, and 0.37 kW at 440 V AC — all at 50/60 Hz. The thermal protection adjustment range is 0.63…1 A, and the control circuit runs on 24 V AC 50/60 Hz. The enclosure carries IP55 protection against dust and water jets, plus IK07 impact resistance per IEC 60529. It meets IEC 60204-1 and IEC 60947-4-1 standards. Cable entry options include 4 entries (2 Pg 13 + 2 Pg 16) on both top and bottom faces. ## Lifecycle status and sourcing reality No direct manufacturer replacement order code is listed in the lifecycle record, so a cross-reference to a current equivalent requires a parametric match on the thermal range (0.63…1 A), coil voltage (24 V AC), enclosure rating (IP55), and motor power class. The 0.63…1 A thermal adjustment range sets the overload protection for the motor full-load current. With AC-3 duty, this starter switches motor loads up to the listed kW ratings — 0.25 kW at 400/415 V is the most common European industrial voltage. The 24 V AC coil is a standard control voltage for safety circuits and PLC-driven contactor banks. IP55 means the enclosure withstands hose-directed water and dust ingress — suitable for washdown areas in food processing or outdoor installations under cover. The polycarbonate housing is corrosion-resistant and lighter than steel, but IK07 impact protection means it should not be mounted where heavy tools or falling objects regularly strike it. The four cable entries (Pg 13 and Pg 16 on both top and bottom) give flexibility for incoming supply and outgoing motor cables without needing an additional junction box.","metaTitle":"TeSys LG7K06B705 Enclosed DOL Starter, 0.63-1A, 24V AC","metaDescription":"Schneider TeSys LG LG7K06B705 enclosed DOL starter. Obsolete, sourced to order. 0.63-1A thermal range, 24V AC coil, IP55.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"0.12 kW at 220/230 V AC 50/60 Hz 0.25 kW at 400/415 V AC 50/60 Hz 0.37 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"24 V AC 50/60 Hz","Thermal protection adjustment range":"0.63...1 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2e707fd6f42ef3160241515751803a3f.pdf","sourceUrl":"https://www.se.com/ie/en/product/LG7K06B705/tesys-lg-enclosed-dol-starter-0-63-1-a-24-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06B705/alternatives.json"},"ai":{"faq":[{"question":"What is the replacement for LG7K06B705?","answer":"No direct manufacturer replacement order code is listed in the lifecycle record. A suitable replacement must be selected based on the thermal protection range (0.63…1 A), coil voltage (24 V AC), enclosure rating (IP55), and motor power class (0.25 kW at 400 V)."},{"question":"What is the motor power rating for LG7K06B705?","answer":"The motor power ratings are 0.12 kW at 220/230 V AC, 0.25 kW at 400/415 V AC, and 0.37 kW at 440 V AC, all at 50/60 Hz."},{"question":"Where can I buy LG7K06B705?","answer":"As an obsolete part, the LG7K06B705 is sourced through independent supply channels. It is quoted to order against an RFQ, with availability and current pricing confirmed at the time of quotation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06B705","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06B705 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}