{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06M702A04","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06M702A04","canonicalUrl":"https://aoctrl.com/schneider/LG7K06M702A04","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06M702A04","rawCanonicalId":null},"summary":{"shortDescription":"TeSys LG enclosed DOL starter, 0.16...0.25 A thermal protection, 220/230 V AC coil, mushroom-head emergency stop, IP55, IK07, polycarbonate.","salesMarkdown":"The TeSys LG7K06M702A04 is an enclosed direct-on-line starter combining a contactor and a circuit-breaker in a single polycarbonate enclosure, rated for 0.06 kW at 400/415 V AC 50/60 Hz (AC-3 utilisation category). The 220/230 V AC coil and thermal protection adjustable from 0.16 to 0.25 A make it a drop-in safety starter for small motor loads — pumps, fans, conveyors — where a local emergency-stop mushroom head is required. IP55 and IK07 ratings mean the enclosure handles washdown and accidental impacts up to 0.5 J — standard for food-and-bev or light industrial environments where the starter mounts near the machine. The 0.06 kW motor power at 400/415 V AC is the headline number — this starter is sized for fractional-horsepower motors, not general-purpose 0.75 kW loads. The AC-3 duty class confirms it switches squirrel-cage motors on and off under full load, not just resistive heating. Thermal protection range 0.16...0.25 A matches the motor full-load current for a 0.06 kW 400 V motor. Set the dial to the motor nameplate FLA; the integrated circuit-breaker provides short-circuit and overload protection in one device, eliminating a separate motor-protective breaker. ## Safety and compliance Designed for safety applications per IEC 60947-4-1 and IEC 60204-1, the mushroom-head push-button (red, twist-to-release) provides local emergency stop. The enclosed format meets machine-guarding requirements where exposed live parts are unacceptable. ## Integration notes Polycarbonate enclosure measures 175 mm wide × 165 mm high × 177 mm deep. Cable entries: four knockouts — two Pg 13 and two Pg 16 on top, same on bottom. Mounts directly to a machine frame or panel; no DIN-rail adapter needed.","metaTitle":"TeSys LG7K06M702A04 Enclosed DOL Starter, 0.06 kW, 220/230 V","metaDescription":"TeSys LG7K06M702A04 enclosed DOL starter, 0.06 kW at 400/415 V AC, AC-3, IP55, IK07, polycarbonate enclosure with mushroom-head emergency stop. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1 IEC 60204-1","Control type":"Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"0.06 kW at 400/415 V AC 50/60 Hz 0.06 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"220/230 V AC 50/60 Hz","Thermal protection adjustment range":"0.16...0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c4ba101ddac0d1a97492ae8eee9eb124.pdf","sourceUrl":"https://www.se.com/uk/en/product/LG7K06M702A04/tesys-lg-enclosed-dol-starter-0-16-0-25-a-220-230-v-ac-coil-no-buttons/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06M702A04/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy LG7K06M702A04 and how is it quoted?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"What is the closest alternative to LG7K06M702A04 in the TeSys family?","answer":"Within the TeSys LG range, the closest sibling is the LG7K06M702A02 (same enclosure and motor power, but with a 110/120 V AC coil instead of 220/230 V AC). Choose based on your control voltage."},{"question":"What compliance documentation is available for LG7K06M702A04?","answer":"The starter complies with IEC 60947-4-1 (contactor-starters) and IEC 60204-1 (safety of machinery). The polycarbonate enclosure carries IP55 and IK07 ratings per IEC 60529. RoHS/REACH declarations are typically available from the manufacturer upon request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06M702A04","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06M702A04 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}