{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06M703","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06M703","canonicalUrl":"https://aoctrl.com/schneider/LG7K06M703","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06M703","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG enclosed DOL starter, order code LG7K06M703, 0.25-0.4 A thermal protection, 220/230 V AC coil, IP55 polycarbonate enclosure.","salesMarkdown":"The Schneider Electric LG7K06M703 is an enclosed direct-on-line (DOL) starter from the TeSys LG range, combining a contactor and a circuit-breaker in a single IP55 polycarbonate enclosure for standard-environment safety applications. Its thermal protection adjustment range of 0.25-0.4 A and AC-3 utilisation category mean it is sized for small motor loads, with a control circuit voltage of 220/230 V AC at 50/60 Hz. The unit is rated for motor power of 0.06 kW at 220/230 V AC, 0.09 kW at 400/415 V AC, and 0.12 kW at 440 V AC, all at 50/60 Hz. It complies with IEC 60947-4-1 (low-voltage switchgear and controlgear for motor starters) and IEC 60204-1 (safety of machinery — electrical equipment), making it suitable for guarding and hazard-zone motor circuits. The LG7K06M703 is classified as obsolete by Schneider Electric. No official successor order code is listed in the lifecycle record, so the replacement path depends on verifying the motor rating (0.25-0.4 A, AC-3) and enclosure requirements (IP55, polycarbonate) against a current TeSys or other Schneider enclosed starter family. ## Physical and environmental fit The enclosure measures 175 mm wide by 165 mm high by 177 mm deep, with a polycarbonate body rated IP55 and IK07 impact resistance. Cable entry is provided via four knockouts: two Pg 13 and two Pg 16 on both the top and bottom faces, allowing flexible conduit or cable-gland routing in the panel. The IP55 rating means the enclosure withstands water jets and dust ingress — suitable for washdown or outdoor installations where the starter must be protected from hose spray. ## Controls and operation The LG7K06M703 includes integrated push-buttons: a white start button, a black stop button, and a red mushroom-head emergency-stop push-button, providing local operator control without external pilot devices.","metaTitle":"Schneider LG7K06M703 TeSys LG Enclosed DOL Starter","metaDescription":"Schneider LG7K06M703 TeSys LG enclosed DOL starter. Obsolete. 0.25-0.4 A thermal protection, 220/230 V AC coil, IP55, IEC 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1 IEC 60204-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"0.06 kW at 220/230 V AC 50/60 Hz 0.09 kW at 400/415 V AC 50/60 Hz 0.12 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"220/230 V AC 50/60 Hz","Thermal protection adjustment range":"0.25...0.4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/df3c72656c5653daad3a3a17eab170fb.pdf","sourceUrl":"https://www.se.com/ie/en/product/LG7K06M703/tesys-lg-enclosed-dol-starter-0-25-0-40-a-220-230-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06M703/alternatives.json"},"ai":{"faq":[{"question":"Is LG7K06M703 still available for purchase?","answer":"The LG7K06M703 is obsolete per Schneider Electric. It is sourced to order against an RFQ through independent distribution — availability and price are confirmed at quote time."},{"question":"What is the replacement for Schneider LG7K06M703?","answer":"No official successor order code is listed. The replacement must be selected based on the motor rating (0.25-0.4 A, AC-3), coil voltage (220/230 V AC), IP55 enclosure, and integrated E-stop, typically from the current TeSys enclosed starter range."},{"question":"What is the motor power rating for LG7K06M703?","answer":"It is rated for 0.06 kW at 220/230 V AC, 0.09 kW at 400/415 V AC, and 0.12 kW at 440 V AC, all at 50/60 Hz."},{"question":"Is LG7K06M703 compatible with GV2ME16?","answer":"The evidence does not list compatibility with GV2ME16. The LG7K06M703 is a complete enclosed DOL starter with integrated thermal protection (0.25-0.4 A), not a separate motor circuit breaker that would be paired with a GV2 series device."},{"question":"Where can I buy LG7K06M703 obsolete part?","answer":"This obsolete part is sourced to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06M703","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06M703 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}