{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06M707","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06M707","canonicalUrl":"https://aoctrl.com/schneider/LG7K06M707","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06M707","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG enclosed DOL starter, LG7K06M707, 1.6-2.5 A thermal protection, 220/230 V AC 50/60 Hz coil, IP55 polycarbonate enclosure with emergency stop and pushbuttons, active production.","salesMarkdown":"The Schneider TeSys LG7K06M707 is an enclosed direct-on-line (DOL) starter — a self-contained motor-starting package that combines a contactor, a circuit-breaker with thermal overload protection, and control devices in a single IP55 polycarbonate enclosure. It's built for AC-3 duty (squirrel-cage motors) and carries safety as its primary application, per the IEC 60947-4-1 and IEC 60204-1 standards it's certified to. The thermal protection adjustment range of 1.6 to 2.5 A sets the motor full-load current window this unit protects. That maps to motor power ratings of 0.37 kW at 220/230 V AC, 0.75 kW at 400/415 V AC, and 1.1 kW at 440 V AC — all 50/60 Hz. The coil pulls 220/230 V AC at line frequency, so it's a straight line-voltage control scheme, no separate control transformer needed for that voltage. ## Where it goes and what it replaces on a line This is a drop-in motor starter for a single machine or a small conveyor section where you want the contactor, overload, and disconnect in one box with local controls. The IP55 rating means it's fine for indoor industrial environments with dust and hose-down — think washdown areas in food processing, packaging lines, or machine tools near coolant mist. It is not rated for direct outdoor exposure (no UV stabilisation stated, and IP55 is splash-proof, not submersible). The polycarbonate body is lighter than a steel enclosure of the same size, which matters if you're mounting it on a moving arm or a gantry.","metaTitle":"Schneider LG7K06M707 TeSys LG Enclosed DOL Starter, 1.6-2.5A","metaDescription":"Schneider TeSys LG7K06M707 enclosed DOL starter. 1.6-2.5A thermal protection, 220/230V AC coil, IP55, includes contactor, breaker, E-stop & pushbuttons.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1 IEC 60204-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"0.37 kW at 220/230 V AC 50/60 Hz 0.75 kW at 400/415 V AC 50/60 Hz 1.1 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"220/230 V AC 50/60 Hz","Thermal protection adjustment range":"1.6...2.5 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$502.06","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/17def77c811e9264498063dd0b93f3ad.pdf","sourceUrl":"https://www.se.com/be/en/product/LG7K06M707/enclosed-dol-startertesys-lg1-62-5a220-230v-ac-coilincluding-1-lc1kgv2me-with-emergency-stop2-pushbuttons/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06M707/alternatives.json"},"ai":{"faq":[{"question":"What is the current rating of LG7K06M707?","answer":"The thermal overload protection on the LG7K06M707 adjusts from 1.6 A to 2.5 A, which covers motors rated 0.37 kW at 230 V, 0.75 kW at 400 V, and 1.1 kW at 440 V in AC-3 duty."},{"question":"What coil voltage does the LG7K06M707 require?","answer":"The control circuit voltage is 220/230 V AC at 50/60 Hz — standard line voltage in many regions, no separate control transformer needed."},{"question":"Is the LG7K06M707 enclosure rated for outdoor use?","answer":"The IP55 rating means it's protected against dust ingress and low-pressure water jets from any direction — suitable for indoor washdown areas but not for direct, prolonged outdoor exposure where rain or UV degradation is a concern."},{"question":"What does the LG7K06M707 include?","answer":"It ships as a complete enclosed DOL starter: a TeSys contactor, a GV2 manual motor starter/circuit-breaker with thermal adjustment 1.6-2.5 A, a red mushroom-head emergency stop, a white start pushbutton, and a black stop pushbutton, all wired in a polycarbonate IP55 enclosure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06M707","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06M707 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}