{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06M708A59","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06M708A59","canonicalUrl":"https://aoctrl.com/schneider/LG7K06M708A59","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06M708A59","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG series, LG7K06M708A59 enclosed DOL starter, 2.5-4 A thermal protection, 220/230 VAC coil, IP55, IK07, polycarbonate enclosure.","salesMarkdown":"The Schneider Electric TeSys LG7K06M708A59 is an enclosed direct-on-line (DOL) starter in the TeSys LG family, combining a contactor, circuit-breaker, and neutral terminal in one IP55 polycarbonate box. It's a safety-rated motor starter for standard environments, built to IEC 60947-4-1 and IEC 60204-1. Rated AC-3 utilisation category, it handles 0.75 kW at 220/230 VAC and 1.5 kW at 400/415 VAC or 440 VAC, 50/60 Hz. The thermal protection adjustment range is 2.5 to 4 A, and the control circuit voltage is 220/230 VAC. The push-button control includes white start, black stop, and a red mushroom-head emergency stop — all integrated into the enclosure lid. Cable entries are 4 x Pg 13 and 2 x Pg 16 at both top and bottom. The AC-3 rating is the key: it's the motor-switching duty class per IEC 60947-4-1, so the 0.75 kW / 1.5 kW figures are what this starter can actually commutate under load — not just carry. The 2.5-4 A thermal protection range sets the motor full-load current window; if your motor FLA falls outside that, this unit won't protect it. IP55 means the enclosure is dust-protected and hose-down resistant — fine for washdown areas but not submersion. IK07 impact rating (1 joule) means it survives a moderate tool drop. The polycarbonate material is standard for this class; it's UV-stable for indoor use but not rated for direct sunlight exposure. The 220/230 VAC coil is a single-voltage control circuit; if your panel runs 24 VDC or 110 VAC, you need a different coil variant in the LG7K family. The neutral terminal is included, simplifying wiring for single-phase control circuits.","metaTitle":"TeSys LG7K06M708A59 Enclosed DOL Starter, 2.5-4 A, 220/230 V","metaDescription":"TeSys LG7K06M708A59 enclosed DOL starter, 2.5-4 A thermal range, 220/230 VAC coil, IP55, IK07. Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60947-4-1 IEC 60204-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"0.75 kW at 220/230 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker Neutral terminal","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"220/230 V AC 50/60 Hz","Thermal protection adjustment range":"2.5...4 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f9a7411e2e6b9e48eab8869736df030f.pdf","sourceUrl":"https://www.se.com/uk/en/product/LG7K06M708A59/tesys-lg-enclosed-dol-starter-2-5-4-a-220-230-v-ac-coil-neutral-term/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06M708A59/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of LG7K06M708A59?","answer":"It is an enclosed DOL starter with AC-3 utilisation category, 2.5-4 A thermal protection range, 0.75 kW at 220/230 VAC or 1.5 kW at 400/415 VAC, 220/230 VAC coil, IP55, IK07."},{"question":"Where can I buy LG7K06M708A59?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What standards does LG7K06M708A59 comply with?","answer":"It complies with IEC 60947-4-1 and IEC 60204-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06M708A59","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06M708A59 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}