{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06N710","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06N710","canonicalUrl":"https://aoctrl.com/schneider/LG7K06N710","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06N710","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG enclosed DOL starter, LG7K06N710, 4-6.3 A thermal protection, 400/415 V AC coil, IP55, polycarbonate enclosure.","salesMarkdown":"The LG7K06N710 is a TeSys LG enclosed direct-on-line starter combining a contactor and circuit-breaker in one IP55 polycarbonate enclosure — a single order code that covers the motor-starting and short-circuit protection for a fixed-speed motor branch. The thermal protection adjustment range of 4 to 6.3 A sets the overload relay trip point, so this starter fits a motor whose full-load current falls inside that window — typically a 2.2 kW motor on a 400/415 V supply, or a 1.1 kW motor on 220/230 V. The 400/415 V AC 50/60 Hz control coil means the starter picks up directly from a 400 V line-to-line signal — no separate control transformer needed in a 400 V panel. Rated for AC-3 utilisation category (IEC 60947-4-1), the contactor is designed for starting and stopping squirrel-cage induction motors — the dominant load type in conveyor, pump, and fan duty. ## Deployment context: where this goes and what it guards The IP55 enclosure and IK07 impact rating make the LG7K06N710 suitable for installation in washdown areas, light industrial environments, or on-machine mounting where dust and water jets are present but high-pressure hose-down is not routine. Cable entries are provided top and bottom — four knockouts per face, sized Pg 13 and Pg 16 — so the starter can be wired into a fixed installation without an additional junction box. The integrated push-button controls (white start, black stop, red mushroom-head emergency stop) mean the starter doubles as a local operator station — no separate push-button enclosure needed for a single-motor cell.","metaTitle":"Schneider TeSys LG7K06N710 Enclosed DOL Starter, 4-6.3 A","metaDescription":"Schneider TeSys LG7K06N710 enclosed DOL starter, 4-6.3 A thermal protection, 400/415 VAC coil, IP55, active production. Sourced to order against an RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"3 kW at 440 V AC 50/60 Hz 1.1 kW at 220/230 V AC 50/60 Hz 2.2 kW at 400/415 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"400/415 V AC 50/60 Hz","Thermal protection adjustment range":"4...6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9bd400f2bb9ac8935d9c684bcc13605a.pdf","sourceUrl":"https://www.se.com/ie/en/product/LG7K06N710/tesys-lg-enclosed-dol-starter-4-6-3-a-400-415-v-ac-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06N710/alternatives.json"},"ai":{"faq":[{"question":"What is the current rating of LG7K06N710?","answer":"The thermal protection adjustment range is 4 to 6.3 A, which sets the overload trip point for the motor branch."},{"question":"Does LG7K06N710 include a circuit breaker?","answer":"Yes, the device composition includes both a contactor and a circuit-breaker in the same enclosure."},{"question":"Does TeSys LG7 starter include overload protection?","answer":"Yes, the LG7K06N710 includes thermal protection adjustable from 4 to 6.3 A."},{"question":"What is the difference between a DOL starter and a star-delta starter?","answer":"A DOL starter applies full line voltage directly to the motor windings at start, producing high inrush current but simple wiring. A star-delta starter reduces inrush by connecting the windings in star during start, then switching to delta for run. The LG7K06N710 is a DOL starter, suited for motors where the supply can handle the starting surge."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06N710","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06N710 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}