{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06Q702","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06Q702","canonicalUrl":"https://aoctrl.com/schneider/LG7K06Q702","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06Q702","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG enclosed DOL starter, LG7K06Q702, 0.16-0.25 A thermal protection range, 380/400 V AC control, IP55, safety-rated with emergency stop.","salesMarkdown":"The Schneider Electric TeSys LG7K06Q702 is an enclosed direct-on-line (DOL) starter from the TeSys LG family, combining a contactor and a circuit-breaker in a single IP55 polycarbonate enclosure. It is a safety-rated starter, meaning it includes an emergency-stop mushroom-head pushbutton alongside start (white I) and stop (black O) pushbuttons, and is designed to meet IEC 60204-1 and IEC 60947-4-1 for machine safety circuits. The thermal protection adjustment range spans 0.16 to 0.25 A, and the motor power rating is 0.06 kW at 400/415 V AC (also 0.06 kW at 440 V AC). The control circuit voltage is 380/400 V AC at 50/60 Hz, so this unit is wired for a 400 V line, not a 230 V control transformer. The 0.16–0.25 A thermal adjustment range governs the motor overload protection — set it to match the full-load current of the connected motor. At 0.06 kW (roughly 1/12 HP) on a 400 V supply, this starter is sized for fractional-horsepower loads: small pumps, fans, or conveyor drives in a safety-monitored circuit. Cable entry is generous: four entries on top and four on bottom, each accepting Pg 13 or Pg 16 glands (two of each per side). That gives flexibility for incoming supply, motor leads, and control wiring without crowding the enclosure.","metaTitle":"Schneider TeSys LG7K06Q702 Enclosed DOL Starter, 0.16-0.25 A","metaDescription":"Schneider Electric TeSys LG7K06Q702 enclosed DOL starter. 0.16-0.25 A thermal protection, IP55, safety-rated. Obsolete — sourced to order against RFQ via independent channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"0.06 kW at 400/415 V AC 50/60 Hz 0.06 kW at 440 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Thermal protection adjustment range":"0.16...0.25 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6e27e19ef6d1cabc4918070c8c40a892.pdf","sourceUrl":"https://www.se.com/ie/en/product/LG7K06Q702/enclosed-safety-starterstesys-control-lg0-160-25a230v-ac-coilincluding-1-lc1kgv2me-with-emergency-stop2-pushbuttons/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06Q702/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy LG7K06Q702?","answer":"We source the LG7K06Q702 through independent distribution channels — broker and surplus networks — and quote it to order against an RFQ. Availability and current pricing are confirmed at the time of your request."},{"question":"What motor can I run with LG7K06Q702?","answer":"The starter is rated for 0.06 kW at 400/415 V AC (AC-3 duty), so it fits fractional-horsepower motors — think small pumps, fans, or light conveyors in a safety circuit. The thermal overload range is 0.16 to 0.25 A, which must match the motor's full-load current."},{"question":"What standards does LG7K06Q702 comply with?","answer":"It complies with IEC 60204-1 (safety of machinery — electrical equipment) and IEC 60947-4-1 (contactors and motor-starters). The enclosure carries IP55 and IK07 ratings per IEC 60529."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06Q702","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06Q702 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}