{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K06Q710A29","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K06Q710A29","canonicalUrl":"https://aoctrl.com/schneider/LG7K06Q710A29","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K06Q710A29","rawCanonicalId":null},"summary":{"shortDescription":"TeSys LG enclosed DOL starter, LG7K06Q710A29, 4…6.3 A thermal protection, 380/400 V AC coil, IP55 polycarbonate enclosure, padlocking device.","salesMarkdown":"The TeSys LG7K06Q710A29 is an enclosed direct-on-line starter from the TeSys LG family, combining a contactor, circuit-breaker, and padlocking device in a single IP55 polycarbonate enclosure. It is designed for safety applications per IEC 60204-1 and IEC 60947-4-1, with AC-3 utilisation category for switching three-phase induction motors. The thermal protection adjustment range of 4…6.3 A sets the overload trip point for the motor circuit — set it to match the motor's full-load current. Motor power capability: 3 kW at 440 V AC, 2.2 kW at 400/415 V AC, and 1.1 kW at 220/230 V AC — all at 50/60 Hz. The IP55 and IK07 ratings mean the enclosure handles hose-down cleaning and low-energy impacts, suitable for standard industrial environments where dust and water jets are present. The LG7K06Q710A29 is available to quote against an RFQ through our network of independent distributors and surplus channels. ## Physical integration and cable entry The enclosure measures 177 mm deep × 175 mm wide × 165 mm high, in polycarbonate. Cable entries: four knockouts — two Pg 13 and two Pg 16 on top, and the same pattern on the bottom. This gives flexibility for top or bottom cable entry in a panel or wall-mount installation. The push-button layout is fixed: white for start (I), black for stop (O), and a red mushroom-head push-button for emergency stop. No auxiliary contact blocks are mentioned in the spec — the emergency stop is a direct mechanical switch on the enclosure face.","metaTitle":"TeSys LG7K06Q710A29 Enclosed DOL Starter, 4…6.3 A, Obsolete","metaDescription":"TeSys LG7K06Q710A29 enclosed DOL starter, 4…6.3 A thermal protection, 380/400 V AC coil, IP55. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"3 kW at 440 V AC 50/60 Hz 1.1 kW at 220/230 V AC 50/60 Hz 2.2 kW at 400/415 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker Padlocking device","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"380/400 V AC 50/60 Hz","Thermal protection adjustment range":"4...6.3 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/73a1dcb9d0e1dded297e4f929affe98d.pdf","sourceUrl":"https://www.se.com/ie/en/product/LG7K06Q710A29/tesys-lg-enclosed-dol-starter-4-6-3-a-380-400-v-ac-coil-padlocking/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K06Q710A29/alternatives.json"},"ai":{"faq":[{"question":"What is the replacement for LG7K06Q710A29?","answer":"The manufacturer's lifecycle record does not list a direct successor order code for the LG7K06Q710A29. For a form-fit-function replacement, contact our sourcing team with your application details (motor kW, coil voltage, enclosure requirements) and we will identify a current equivalent from the TeSys family or another manufacturer."},{"question":"What is the current rating of LG7K06Q710A29?","answer":"The thermal protection adjustment range is 4…6.3 A. This is the overload relay setting range, not a continuous current rating — set it to the motor's full-load current within that window. The contactor and circuit-breaker are rated for AC-3 switching duty at those currents."},{"question":"Where can I buy LG7K06Q710A29?","answer":"Submit an RFQ through our sourcing desk; we will confirm availability and pricing from our distributor network at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K06Q710A29","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K06Q710A29 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}