{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LG7K09N714A12","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LG7K09N714A12","canonicalUrl":"https://aoctrl.com/schneider/LG7K09N714A12","factsUrl":"https://aoctrl.com/api/mcp/products/LG7K09N714A12","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LG enclosed DOL starter, LG7K09N714A12, 6-10 A thermal adjustment, 400/415 V AC coil, 4 kW at 400 V, IP55 polycarbonate enclosure.","salesMarkdown":"The Schneider TeSys LG enclosed DOL starter LG7K09N714A12 is a direct-on-line motor starter in an IP55 polycarbonate enclosure, rated for 4 kW at 400/415 V AC in AC-3 duty. Thermal protection is adjustable 6-10 A via the built-in circuit-breaker, and the control circuit runs on 400/415 V AC 50/60 Hz. The assembly includes a contactor, circuit-breaker, and short-circuit signalling block, plus a push-button start (white I), stop (black O), and red mushroom-head emergency stop — all pre-wired inside the enclosure. The IP55 rating means the enclosure is dust-protected and resists water jets from any direction — suitable for washdown areas or outdoor installation under a canopy. The polycarbonate housing gives IK07 impact resistance, so it survives incidental tool bumps on the panel face. This starter is sized for a 4 kW, 400 V three-phase motor in AC-3 switching duty — that covers most standard 4-pole induction motors on pumps, fans, and small conveyors. The 6-10 A thermal adjustment range matches motors drawing roughly 7-9 A full-load at 400 V. Four cable entries (2x Pg 13 + 2x Pg 16 top and bottom) give flexibility for incoming supply and motor leads in a panel or standalone box. Enclosure dimensions are 165 mm high, 175 mm wide, 177 mm deep — compact enough for a wall-mount or machine-side bracket. The polycarbonate material is lighter than steel and won't corrode in humid environments. The LG7K09N714A12 is designed to IEC 60204-1 (safety of machinery — electrical equipment) and IEC 60947-4-1 (contactors and motor-starters). These are the core standards for industrial motor control in Europe and most export markets. The IK07 impact rating and IP55 ingress protection are tested per IEC 60529.","metaTitle":"TeSys LG7K09N714A12 Enclosed DOL Starter, 6-10 A, 4 kW, IP55","metaDescription":"Schneider TeSys LG enclosed DOL starter LG7K09N714A12. 6-10 A thermal protection, 4 kW at 400 V AC-3, IP55, active production. Sourced to order; RFQ for current pricing.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Motor Starters"],"specifications":{"Depth":"177 mm","Range":"TeSys","Width":"175 mm","Height":"165 mm","Material":"Polycarbonate","Standards":"IEC 60204-1 IEC 60947-4-1","Control type":"Push-button start white I Push-button stop black O Mushroom head push-button emergency stop red","Product name":"TeSys LG","Motor power kW":"4 kW at 400/415 V AC 50/60 Hz 4 kW at 440 V AC 50/60 Hz 1.5 kW at 220/230 V AC 50/60 Hz","lifecycle_stage":"current","Device short name":"LG7K","Cable entry number":"4 2 Pg 13 + 2 Pg 16 top 4 2 Pg 13 + 2 Pg 16 bottom","Device application":"Safety","Device composition":"Contactor Circuit-breaker Short-circuit signalling block","Utilisation category":"AC-3","IK degree of protection":"IK07 conforming to IEC 60529","IP degree of protection":"IP55 conforming to IEC 60529","Product or component type":"Enclosed DOL starter","Environmental characteristic":"Standard environment","[Uc] control circuit voltage":"400/415 V AC 50/60 Hz","Thermal protection adjustment range":"6...10 A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f850b519fe630bb05fd0ddde90608d5d.pdf","sourceUrl":"https://www.se.com/uk/en/product/LG7K09N714A12/tesys-lg-enclosed-dol-starter-6-10-a-400-415-v-ac-coil-signalling/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LG7K09N714A12/alternatives.json"},"ai":{"faq":[{"question":"Where can I buy LG7K09N714A12 and get a price?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Send us the order code and quantity; we confirm availability and current pricing at quote time."},{"question":"What motor does LG7K09N714A12 fit?","answer":"It is rated for a 4 kW three-phase motor at 400/415 V AC in AC-3 duty, with thermal adjustment 6-10 A. That covers most standard 4-pole induction motors in that power class."},{"question":"What is the IP rating and enclosure material?","answer":"IP55 per IEC 60529, polycarbonate housing with IK07 impact resistance. Suitable for washdown or outdoor use where direct water jets may hit the enclosure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LG7K09N714A12","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LG7K09N714A12 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}