{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LLF37060D33","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LLF37060D33","canonicalUrl":"https://aoctrl.com/schneider/LLF37060D33","factsUrl":"https://aoctrl.com/api/mcp/products/LLF37060D33","rawCanonicalId":null},"summary":{"shortDescription":"Square D LLF37060D33 3P 600A CB|Square D LLF37060D33 3P 600A CB","salesMarkdown":null,"metaTitle":"Schneider LLF37060D33 Residual Current Breaker","metaDescription":"Schneider Electric LLF37060D33 3-pole residual current circuit breaker, 600 A, for earth fault protection in industrial systems.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Color":"Black","Depth":"4.3 in (110 mm)","Range":"PowerPact","Width":"5.5 in (140 mm)","Height":"13.4 in (340 mm)","Category":"US10DE201116","AWG gauge":"2 x AWG 2/0...500 kcmil aluminium/copper","Standards":"UL CSA NEMA NOM-003-SCFI-2000 IEC 60947-2","Control Type":"Toggle","Product name":"PowerPact L","Mounting mode":"Unit mount busbar)","Number of Poles":"3P","lifecycle_stage":"unknown","Local signalling":"Switched off (OFF) 1 trip indicator green)","Mounting Support":"Busbar","Pollution degree":"3 IEC 60947-1","Breaking capacity":"125 kA 240 V AC 50/60 Hz UL 489 100 kA 480 V AC 50/60 Hz UL 489 50 kA 600 V AC 50/60 Hz UL 489 18 kA 250 V DC UL 489 50 kA 500 V DC UL 489","Device short name":"L-Frame","Tightening torque":"442.5 lbf.in (50 N.m) 0.1...0.4 in² (70...240 mm²) (2 x AWG 2/0...500 kcmil)","Device Application":"Distribution","Operating altitude":"< 6561.68 ft (2000 m) without derating 5000 m with derating","Terminal identifier":"AL600LS52K3","Trip unit technology":"Thermal-magnetic","Utilisation category":"Category A","Electrical connection":"Busbar connection, line Busbar connection, load","Nbr. of units in pkg.":"1","Breaking capacity code":"L","Communication interface":"Modbus Ethernet","IP degree of protection":"Front cover IP40","Magnetic tripping current":"1500...3000 A","Product or Component Type":"Circuit breaker","Suitability for isolation":"Yes IEC 60947-2","Circuit breaker application":"HACR rated","Power wire stripping length":"1.2 in (31 mm) 2.4 in (61 mm)","[Ui] rated insulation voltage":"750 V IEC 60947-2","[Ue] rated operational voltage":"500 V DC","Ambient Air Temperature for Storage":"-58...185 °F (-50...85 °C)","Ambient Air Temperature for Operation":"-13...158 °F (-25...70 °C)","[Ics] rated service breaking capacity":"125 kA 220/240 V AC 50/60 Hz IEC 60947-2 100 kA 380/440/415 V AC 50/60 Hz IEC 60947-2 50 kA 500/525 V AC 50/60 Hz IEC 60947-2 20 kA 250 V DC IEC 60947-2 20 kA 500 V DC IEC 60947-2","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c6a0f0df398a7d8a0079cffba8451dea.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LLF37060D33/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LLF37060D33","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LLF37060D33 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}