{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LMC20A1309","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LMC20A1309","canonicalUrl":"https://aoctrl.com/schneider/LMC20A1309","factsUrl":"https://aoctrl.com/api/mcp/products/LMC20A1309","rawCanonicalId":null},"summary":{"shortDescription":"Lexium motion servo drive Controller - 24 V DC - 0.5 A","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Marking":"CE","Standards":"EN/IEC 61800-3 environment 1 EN/IEC 61800-5-1 EN/IEC 61800-3 environment 2","Cycle time":"2 ms for 4 synchronized axes 4 ms for 8 synchronized axes","Insulation":"Discrete input for between input channels with internal logic via optical coupler Event-triggered input for between input channels with internal logic via optical coupler Logic output for between output channels with internal logic via optical coupler Master encoder input for 2500 V Touch probe input for between input channels with internal logic via optical coupler","Web server":"Class C20, Modbus TCP network","Data format":"8 bits, no parity, 1 stop for Modbus protocol","Filter time":"0.5 µs at state 0 for touch probe input(s) 1 µs at state 1 for touch probe input(s) 15 µs at state 1 for discrete input(s) 15 µs at state 1 for event-triggered input(s) 70 µs at state 0 for discrete input(s) 70 µs at state 0 for event-triggered input(s)","Memory type":"Flash EPROM 1 MB application NVRAM 60 kB data storage RAM 1 MB application","Exchange mode":"Half duplex and full duplex Modbus TCP network","Response time":"150 µs at state 1 for logic output 250 µs at state 0 for logic output","Component name":"LMC","Connector type":"1 RJ45 for Modbus protocol 1 RJ45 for Modbus TCP network 9-way male SUB-D connector for CANopen machine bus 9-way male SUB-D connector for CANopen Motionbus Screw-type, 5 contacts, 5.08 pitch for DeviceNet fieldbus","Inrush current":"10 A for 0.2 ms","Realtime clock":"Built-in for 20 days","lifecycle_stage":"unknown","Installed device":"8 Lexium 05 or Lexium 15 servo drives or SD3 28A stepper drives for CANopen Motionbus","Local signalling":"1 LED - activity for CANopen machine bus 1 LED - activity for CANopen Motionbus 1 LED - activity for DeviceNet fieldbus 1 LED - activity for Modbus protocol 1 LED - activity for Modbus TCP network","Method of access":"Master CANopen machine bus Master CANopen Motionbus Slave Modbus protocol","Range of product":"Lexium Controller","Shock resistance":"15 gn for 11 ms conforming to EN/IEC 60068-2-27","Relative humidity":"10...95 % for operation, without condensation 5...95 % for storage, without condensation conforming to IEC 61131-2","Transmission rate":"1 Mbps for bus length of 15 m for CANopen machine bus 1 Mbps for bus length of 15 m for CANopen Motionbus 10/100 Mbps, autodetected for Modbus TCP network 125 kbps, 250 kbps or 500 kbps for DeviceNet fieldbus 19.6 kbps or 38.4 kbps for Modbus protocol 250 kbps for bus length of 250 m for CANopen Motionbus 50 kbps for bus length of 1000 m for CANopen machine bus 500 kbps for bus length of 80 m for CANopen Motionbus","Operating altitude":"0...2000 m","Physical interface":"2-wire RS 485 for Modbus protocol 2-wire RS 485 for Modbus TCP network Ethernet 2 for Modbus TCP network","Discrete input type":"12 mA master encoder input for 2 kOhm 7 mA discrete input for 3 kOhm 7 mA event-triggered input for 3 kOhm 7 mA touch probe input for 3 kOhm","Input compatibility":"Encoder with open collector output, 5 V power supplied for master encoder Encoder with push-pull output, 5 V power supplied for master encoder Encoder with RS422 compatible differential outputs, 5 or 24 V power supplied for master encoder Universal encoder with SSI output, 24 V power supplied for master encoder","Number of addresses":"1...32 for CANopen machine bus 1...63 for DeviceNet fieldbus 1...247 for Modbus protocol","Discrete input logic":"Positive logic (source) for discrete input","Mode of transmission":"RTU for Modbus protocol","Power Supply Voltage":"24 V","Type of polarization":"10 kOhm for Modbus protocol","Vibration resistance":"1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm (f= 5...13 Hz) conforming to EN/IEC 60068-2-6","Application structure":"1 master task 1 auxiliary task 2 event-triggered tasks","Communication service":"10 PDOs per slave for CANopen machine bus 2 SDOs per cycle for CANopen machine bus CiA DSP 301 V4.02 for CANopen machine bus CiA DSP 405 for CANopen machine bus Note guarding, heartbeat for CANopen machine bus 2 PDOs per slave (1 transmit and 1 receive) for CANopen Motionbus 2 SDOs per cycle (1 read and 1 write) for CANopen Motionbus CiA DSP 301 V4.02 for CANopen Motionbus CiA DSP 405 for CANopen Motionbus Emergency for CANopen Motionbus Note guarding, heartbeat for CANopen Motionbus Communication scanner assemblies 100 and 101 for DeviceNet fieldbus Monitoring inhibitable for DeviceNet fieldbus Periodic exchange mode on inputs : polled, change of state, cyclic for DeviceNet fieldbus Periodic exchange mode on outputs : polled for DeviceNet fieldbus Time out can be set for DeviceNet fieldbus Configurable time out for Modbus protocol Diagnostics (08) for Modbus protocol Read device identification (43) for Modbus protocol Read holding registers (03), 121 words maximum for Modbus protocol Write multiple registers (16), 121 words maximum for Modbus protocol Write single register (06) for Modbus protocol BOOTP for Modbus TCP network DHCP for Modbus TCP network Diagnostics (08) for Modbus TCP network FTP for web server for Modbus TCP network Monitoring inhibitable for Modbus TCP network Read device identification (43) for Modbus TCP network Read holding registers (03), 121 words maximum for Modbus TCP network SNMP for Modbus TCP network Time out adjustable from 0.5...60 s for Modbus TCP network Write multiple registers (16), 121 words maximum for Modbus TCP network Write single register (06) for Modbus TCP network","Discrete input number":"1 master encoder discrete input(s) 2 event-triggered discrete input(s) 2 touch probe discrete input(s) 8 discrete discrete input(s)","Discrete output logic":"2 positive logic (source)","Electrical connection":"1 HE-10 connector discrete input 1 HE-10 connector event-triggered input 1 HE-10 connector touch probe input 1 high density 15-way female SUB-D connector master encoder input","Discrete input voltage":"5.5 V DC for master encoder input 24 V DC (voltage limits: 19...30 V) for discrete input 24 V DC (voltage limits: 19...30 V) for event-triggered input 24 V DC (voltage limits: 19...30 V) for touch probe input","Discrete output number":"8","Maximum supply current":"0.5 A","Communication data link":"LLC : IEEE 802.2 for Modbus TCP network MAC : IEEE 802.3 for Modbus TCP network","Discrete output current":"200 mA","Discrete output voltage":"24 V DC 19...30 V","IP degree of protection":"IP20","Power Supply Circuit Type":"DC","Product or component type":"Motion servo drive controllers","Communication network type":"ICMP IP conforming to RFC791","Communication port protocol":"CANopen Motionbus Modbus protocol Modbus TCP network CANopen machine bus DeviceNet fieldbus","Power Supply Voltage Limits":"19...30 V","Communication transport type":"TCP conforming to RFC793 UDP","Electromagnetic compatibility":"Electrostatic discharge level 3 conforming to EN/IEC 61000-4-2 Immunity to electrical transients level 4 conforming to EN/IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to EN/IEC 61000-4-3 Voltage/current impulse level 3 conforming to EN/IEC 61000-4-5","Exact time for 1 Kinstruction":"< 120 µs (in structured language, 60 % Boolean, 20 % numerical, 20 % floating point)","Ambient air temperature for storage":"-25...70 °C conforming to IEC 61131-2","Maximum output short-circuit current":"1 A","Ambient air temperature for operation":"0...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,282.25","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/19deca3cd6cb5b06b2faa8fc37cafe8f.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LMC20A1309/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LMC20A1309","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LMC20A1309 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}