{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D40004EW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D40004EW","canonicalUrl":"https://aoctrl.com/schneider/LP1D40004EW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D40004EW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LP1D contactor, 4 poles, AC-1 440V 60 A, coil 48 V DC.","salesMarkdown":"The LP1D40004EW is a 4-pole contactor from the TeSys Deca range, rated for 60 A in AC-1 duty at 440 V with a 48 V DC coil. That AC-1 rating covers resistive loads — heaters, lighting banks, or transformer primaries — where the switching current stays close to the load current. For motor duty (AC-3, AC-3e, AC-4) the rated current will be lower; the spec table carries the exact figures for your load type. ## Standards and environmental fit The contactor is certified to EN 60947-1, IEC 60947-4-1, VDE 0660, JEM 1038, BS 5424, and NF C 63-110 — the full suite of industrial control-gear standards. That means it is accepted for panel builds in Europe, the UK, and markets following IEC or JEM norms. Operates from -40 to 60 °C ambient (derated above 60 °C up to 70 °C), and stores from -60 to 80 °C. IP2X finger-safe protection on the contactor body — fine for enclosed panel mounting; not rated for washdown environments. Shock and vibration ratings are given for both open and closed contactor states — useful when specifying for mobile or high-vibration equipment. ## Switching timing and mounting That is a standard safety interlock feature — ensures the break-before-make gap is wide enough to prevent a momentary short between contact sets in reversing or star-delta circuits. Mounts on a rail or plate; dimensions are 85 mm wide, 127 mm high, 182 mm deep. That depth is the body depth — factor in wiring space and any auxiliary block overhang when laying out the panel.","metaTitle":"TeSys LP1D40004EW 4-pole contactor, 60 A AC-1, 48 VDC coil","metaDescription":"Active-production TeSys Deca contactor, 4 poles, AC-1 440V 60 A, coil 48 V DC. EN/IEC 60947-4-1, IP2X. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"182 mm","Width":"85 mm","Height":"127 mm","Standards":"EN 60947-1 VDE 0660 IEC 60947-4-1 JEM 1038 IEC 60947-1 BS 5424 EN 60947-4-1 NF C 63-110","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Rail Plate","Non-overlap time":"1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts","Range of product":"TeSys Deca","Device short name":"LP1D","Poles description":"4P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Mechanical robustness":"Shocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)","IP degree of protection":"IP2X conforming to IEC 60529 IP2X conforming to VDE 0106","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-60...80 °C storage -40...60 °C operation 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b66a3ba9f33d2f3718348531b386a4db.pdf","sourceUrl":"https://www.se.com/nl/en/product/LP1D40004EW/contactor-tesys-lp1d-4-poles-ac1-440v-60-a-coil-48-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D40004EW/alternatives.json"},"ai":{"faq":[{"question":"What standards does this contactor comply with?","answer":"It complies with EN 60947-1, IEC 60947-4-1, VDE 0660, JEM 1038, BS 5424, NF C 63-110, and has fire resistance to 850 °C per IEC 60695-2-1 with UL 94 V-1 flame retardance."},{"question":"What is the AC-1 rating and what loads does it cover?","answer":"The AC-1 rating is 60 A at 440 V, covering resistive loads such as heaters, lighting, and transformer primaries. For motor loads (AC-3, AC-4) the rated current will be lower."},{"question":"What is the ambient temperature range for this contactor?","answer":"Operating range is -40 to 60 °C (with derating up to 70 °C), storage range is -60 to 80 °C. No derating required up to 3000 m altitude."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D40004EW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D40004EW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}