{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D40004FW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D40004FW","canonicalUrl":"https://aoctrl.com/schneider/LP1D40004FW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D40004FW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LP1D40004FW, 4-pole contactor, 60 A AC-1 at 440 V, 110 V DC coil, screw clamp terminals, obsolete.","salesMarkdown":"The LP1D40004FW is a 4-pole (4NO) contactor from the TeSys Deca range, rated 60 A in AC-1 utilisation category at 440 V — that's the resistive load rating, so it handles heater banks, lighting, or transformer primaries at that current. The 110 V DC coil means it's for control circuits running on DC voltage, common in battery-backed or industrial DC systems. Terminals are screw-clamp type, which is the standard for panel wiring in most regions. It's also listed for AC-3 and AC-3e duty (motor switching), though the AC-1 figure is the headline rating here. The part carries approvals under VDE 0660, IEC 60947-4-1, EN 60947-4-1, BS 5424, and NF C 63-110, so it's accepted across European and UK installations. Flame retardance is V1 per UL 94, and fire resistance is 850 °C per IEC 60695-2-1. If you need a drop-in replacement with the same coil voltage and pole count, the closest functional match would be a current-production TeSys Deca contactor with 110 V DC coil and 4 poles — but pinout and mounting dimensions should be cross-checked against the panel layout before committing the BOM line. Dimensions are 182 mm deep, 85 mm wide, 127 mm tall. Mounting is on a rail or plate — the part accepts both DIN-rail snap-on and panel-mount screw fixing. IP2X finger protection per IEC 60529 means it's safe for open-panel use where accidental contact is a concern.","metaTitle":"TeSys Deca LP1D40004FW 4P Contactor, 60A AC-1, 110V DC Coil","metaDescription":"Obsolete TeSys Deca LP1D40004FW 4P contactor, 60A AC-1 at 440V, 110V DC coil, screw terminals. Sourced to order against RFQ. UL/CSA/CE listed.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"182 mm","Width":"85 mm","Height":"127 mm","Standards":"VDE 0660 IEC 60947-1 BS 5424 NF C 63-110 IEC 60947-4-1 EN 60947-4-1 EN 60947-1 JEM 1038","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Rail Plate","Non-overlap time":"1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts","Range of product":"TeSys Deca","Device short name":"LP1D","Poles description":"4P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Mechanical robustness":"Shocks contactor open (8 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)","IP degree of protection":"IP2X conforming to IEC 60529 IP2X conforming to VDE 0106","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-5...60 °C -40...70 °C at Uc"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2525741bb1312cd7633e0c52d0ed2dd4.pdf","sourceUrl":"https://www.se.com/nl/en/product/LP1D40004FW/contactor-tesys-deca-4p4noac1-440v-60a110v-dc-coil-screw-clamp-terminal/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D40004FW/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 4-pole (4NO) contactor rated 60 A in AC-1 (resistive) utilisation category at 440 V, with a 110 V DC coil. It also covers AC-3 and AC-3e motor-switching duty. Screw-clamp terminals are standard."},{"question":"What compliance standards does this part meet?","answer":"It is approved under VDE 0660, IEC 60947-4-1, EN 60947-4-1, BS 5424, NF C 63-110, and JEM 1038. Flame retardance is V1 per UL 94, and fire resistance is 850 °C per IEC 60695-2-1."},{"question":"What are the physical dimensions of LP1D40004FW?","answer":"Depth is 182 mm, width is 85 mm, height is 127 mm. It mounts on a rail or plate."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D40004FW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D40004FW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}