{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D40004MW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D40004MW","canonicalUrl":"https://aoctrl.com/schneider/LP1D40004MW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D40004MW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LP1D, 4-pole contactor, AC-1 440V 60 A, coil 220 V DC, obsolete.","salesMarkdown":"The LP1D40004MW is a 4-pole contactor from the TeSys Deca range, rated for 60 A in AC-1 duty at 440 V with a 220 V DC coil. It's designed for resistive load switching and carries utilisation categories AC-1, AC-3, AC-3e, and AC-4, making it suitable for motor starting and general switching in control panels. Mounts on plate or rail, with IP2X finger protection per IEC 60529 and VDE 0106, so it's safe for open-panel installations where accidental contact is a concern. Compliance covers IEC 60947-1, EN 60947-4-1, BS 5424, and several national standards. The AC-1 rating of 60 A at 440 V governs resistive loads (heaters, lighting). For motor duty, the AC-3 rating will be lower — that's the figure to check against your motor's full-load current. The 220 V DC coil is unusual for this frame size; ensure your control supply matches exactly, as DC coils have a narrower pick-up/drop-out band than AC. If your application sequences contactors, this timing matters for interlocking. Operating altitude of 3000 m without derating covers most installations outside high-altitude mining or mountain sites. Above that, expect reduced dielectric withstand and thermal capacity. ## Integration notes Dimensions are 85 mm wide, 127 mm high, 182 mm deep — a standard TeSys Deca 4-pole footprint. Plate or rail mount, so it retrofits into existing Deca backplates or DIN-rail enclosures. The 182 mm depth is the front-to-back projection including arc chutes; verify clearance against enclosure doors or busbars. Ambient operating range is -40 to 60 °C, with derating required above 60 °C up to 70 °C. Storage range extends to -60 to 80 °C.","metaTitle":"TeSys LP1D40004MW Contactor, 4P, AC-1 60A, 220 VDC Coil","metaDescription":"Obsolete TeSys LP1D40004MW 4-pole contactor, 60 A AC-1 at 440 V, 220 VDC coil. Sourced to order against RFQ. IEC/EN 60947-4-1, IP2X.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"182 mm","Width":"85 mm","Height":"127 mm","Standards":"IEC 60947-1 EN 60947-4-1 BS 5424 IEC 60947-4-1 EN 60947-1 NF C 63-110 JEM 1038 VDE 0660","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Plate Rail","Non-overlap time":"1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts","Range of product":"TeSys Deca","Device short name":"LP1D","Poles description":"4P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Mechanical robustness":"Shocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)","IP degree of protection":"IP2X conforming to IEC 60529 IP2X conforming to VDE 0106","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-60...80 °C storage -40...60 °C operation 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cc725b403bdff8bb01e2e85c94996c6e.pdf","sourceUrl":"https://www.se.com/au/en/product/LP1D40004MW/contactor-tesys-lp1d-4-poles-ac1-440v-60-a-coil-220-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D40004MW/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"4 poles, AC-1 rating of 60 A at 440 V, coil 220 V DC. Utilisation categories include AC-1, AC-3, AC-3e, and AC-4. IP2X finger protection, operating temperature -40 to 60 °C."},{"question":"What compliance documentation is available for this part?","answer":"It complies with IEC 60947-1, EN 60947-4-1, BS 5424, and several other national standards. Fire resistance is 850 °C per IEC 60695-2-1, and flame retardance is UL 94 V1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D40004MW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D40004MW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}