{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D40008JW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D40008JW","canonicalUrl":"https://aoctrl.com/schneider/LP1D40008JW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D40008JW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys D contactor, 4 poles (2NO + 2NC), AC-1 440V 60 A, coil 12 V DC, obsolete.","salesMarkdown":"The Schneider Electric LP1D40008JW is a TeSys D series contactor with four poles arranged as 2 normally-open and 2 normally-closed contacts, rated for resistive loads at AC-1 60 A at 440 V, with a 12 V DC coil. It is designed for switching resistive loads in control panels, with a rated operational voltage covering power circuit applications and a mechanical robustness that withstands shocks up to 10 Gn when open and 15 Gn when closed, plus vibrations up to 4 Gn across 5-300 Hz when closed. The contactor meets multiple international standards including IEC 60947-4-1, EN 60947-4-1, VDE 0660, and BS 5424, with a fire resistance rating of 850 °C per IEC 60695-2-1 and a V1 flame retardance per UL 94. For procurement, this means the part is sourced through surplus or broker channels against an RFQ — no standard factory lead time applies. No official successor order code is provided in the lifecycle record, so a parametric cross-reference to a current TeSys D variant would need to be evaluated based on the specific application requirements (4-pole, 2NO+2NC, AC-1 60A, 12VDC coil). The 12 V DC coil is a low-voltage control circuit — common in PLC-driven panels or battery-backed systems, but verify your control voltage matches exactly since DC coils are polarity-sensitive and have different pull-in characteristics than AC coils. Mounting is on plate or rail (DIN rail compatible), with dimensions of 85 mm width, 127 mm height, and 182 mm depth — fits standard TeSys D panel footprints. The contactor operates from -40 to 60 °C without derating, and up to 70 °C with derating, with storage from -60 to 80 °C — suitable for most industrial environments including unheated enclosures. It is rated for operation up to 3000 m altitude without derating, and carries IP2X finger protection per IEC 60529 and VDE 0106.","metaTitle":"Schneider LP1D40008JW TeSys D Contactor, 4P, AC-1 60A, 12VDC","metaDescription":"Obsolete Schneider TeSys D contactor LP1D40008JW, 4 poles (2NO+2NC), AC-1 60A at 440V, 12VDC coil. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"182 mm","Range":"TeSys","Width":"85 mm","Height":"127 mm","Standards":"VDE 0660 NF C 63-110 IEC 60947-1 IEC 60947-4-1 EN 60947-1 BS 5424 EN 60947-4-1 JEM 1038","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Plate Rail","Non-overlap time":"1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts","Range of product":"TeSys D","Device short name":"LP1D","Poles description":"4P","Climatic withstand":"conforming to IACS E10 exposure to damp heat","Operating altitude":"3000 m without derating","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical robustness":"Shocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)","IP degree of protection":"IP2X conforming to IEC 60529 IP2X conforming to VDE 0106","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-60...80 °C storage -40...60 °C operation 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0362043e45c95bc1f3604480fab2d5a9.pdf","sourceUrl":"https://www.se.com/au/en/product/LP1D40008JW/contactor-tesys-deca-4-poles-2no-+-2nc-ac1-440v-60-a-coil-12-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D40008JW/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LP1D40008JW?","answer":"It is a 4-pole contactor (2NO + 2NC) rated AC-1 60 A at 440 V for resistive loads, with a 12 V DC coil. It measures 85 mm wide, 127 mm high, and 182 mm deep, and mounts on plate or DIN rail."},{"question":"What standards does this contactor comply with?","answer":"It complies with IEC 60947-4-1, EN 60947-4-1, VDE 0660, BS 5424, JEM 1038, and NF C 63-110. It also meets 850 °C fire resistance per IEC 60695-2-1 and V1 flame retardance per UL 94."},{"question":"How do I source this obsolete part?","answer":"Since it is obsolete, it is available through surplus or independent distributor channels. Submit an RFQ for current availability and pricing — no standard factory lead time applies."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D40008JW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D40008JW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}